Inspection , Testing & Repair for Phoenix Control Valves
Closed · Arizona · Last reported Dec 2025
Source: Arizona Purchasing Group
Please note : This is a Sole Source Notification . 1 . Contractor Requirements 1 . 1 . Contractor shall be certified by Phoenix Controls in : 1 . 1 . 1 . Phoenix Controls ’ Sales and Applications . 1 . 1 . 2 . Start - up , testing , and troubleshooting for all Phoenix Controls ’ products . 2 . Contractor Responsibilities 2 . 1 . The
- Status
- Closed
- Sector
- Advanced Electronics, Power Generation (CCGT), Commercial
- Location
- Arizona, United States of America
- Updated
- 3 Nov 2026
- Source
- Arizona Purchasing Group
ConstructChat
Ask ConstructChat about Inspection , Testing & Repair for Phoenix Control Valves
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | Please note : This is a Sole Source Notification . 1 . Contractor Requirements 1 . 1 . Contractor shall be certified by Phoenix Controls in : 1 . 1 . 1 . Phoenix Controls ’ Sales and Applications . 1 . 1 . 2 . Start - up , testing , and troubleshooting for all Phoenix Controls ’ products . 2 . Contractor Responsibilities 2 . 1 . The Contractor shall provide technicians with intimate knowledge and expertise in Phoenix Control valves ventilation system to evaluate the performance of the ASPHL ventilation system and generate a monthly inspection report . The testing and inspection services include , but are not limited to the following : 2 . 1 . 1 . Verify that each fume hood is being controlled at the design flow volume and adjust as required . 2 . 1 . 2 . Check each sash sensor physical condition and operation and adjust as required . 2 . 1 . 3 . Verify the proper operation of each fume hood monitor and adjust as required . 2 . 1 . 4 . Verify the proper operation of each fume hood exhaust valve and adjust as required . 2 . 1 . 5 . Verify the proper operation of tracking supply air valves and adjust as required . 2 . 1 . 6 . Check wire connections and terminations at the fume hood . 2 . 1 . 7 . Check AC and DC voltage level and power supply conditions . 2 . 1 . 8 . Verify operation of Phoenix Controls server and add new system updates , including software if available . 2 . 1 . 9 . Check static pressure upstream and static pressure drop across fume hood exhaust , general exhaust and supply air valves . 2 . 1 . 10 . Verify that each fume hood ’ s average face velocity is a minimum of 100 feet per minute ( FPM ) or as directed by ADHS and adjust average face velocity as required . 2 . 1 . 11 . Verify system mechanisms maintain appropriate negative room pressurization and adjust as required . 2 . 1 . 12 . Ensure all devices are online and communication are working between the building automation system ( BAS ). |
Location
Country | United States of America (USA) |
State | Arizona |
Source
Source | Arizona Purchasing Group |
URL |
More Details
Record type | Tender |
Sector | Advanced Electronics, Power Generation (CCGT), Commercial |
Article published date | 2026-03-27 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Advanced Electronics tenders in United States of America
- RFP - Pro-Tem Hearing Examiner
- RFP - Thurston County Lake Management Districts Submerged Aquatic Vegetation Control
- Request/Notice for Qualifications for Biosolids Digester Fac...
- RFQ - Boston Harbor & Tamoshan Water & Sewer System Improvement Design, CP A053A&B, A511A&B
- RFP - Moderate Risk Waste transportation and disposition management of the County's moderate risk waste collected at HazoHouse
- RFP - Collection, Transportation, Recycling, and/or Disposal of Used Oil, Antifreeze, and Oil Filters
- FURNISHING DELIVERY AND INSTALLATION OF FLASHOVER SIMULATOR
- Nikon D5 Camera Upgrade for Existing DCS5 Alternative Light System
