The Environmental and Industrial Hazards (EIH) Laboratory at the Institute of Naval Medicine requires two Ion Chromatography Systems to replace the current Ion Chromatograph which has reached the end of its useful life and to provide additional capability according to new requirements. The systems will primarily be used for analysis of anions in raw, potable and bottled water samples in accordance

Status
Closed
Sector
Water Supply and Storage, Fertilizers, Manufacturing (Industrial), Commercial, Hospital
Location
United Kingdom
Updated
3 Nov 2026
Source
Find a Tender Service (UK)

ConstructChat

Ask ConstructChat about Ion Chromatography Systems, Autosampler and 10 Year Preventative Maintenance

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Ion Chromatography Systems, Autosampler and 10 Year Preventative Maintenance” is a tender record in Taiyo, linked to the Water Supply and Storage sector. It is issued for works, goods, or services related to United Kingdom.

Participants

Not available for this record.

Status

Original status

complete

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

The Environmental and Industrial Hazards (EIH) Laboratory at the Institute of Naval Medicine requires two Ion Chromatography Systems to replace the current Ion Chromatograph which has reached the end of its useful life and to provide additional capability according to new requirements. The systems will primarily be used for analysis of anions in raw, potable and bottled water samples in accordance with the requirements of service doctrine1, 2, 3 and UK drinking water legislation4, 5, but other matrices will include environmental samples such as groundwater, surface water and wastewater. One Ion Chromatograph must be capable of analysing 9 anions (fluoride, chlorite, chloride, nitrite, chlorate, bromide, nitrate, sulphate and phosphate) using conductivity detection. The other Ion Chromatograph must be capable of analysing bromate in samples with elevated levels of chloride with post column derivatisation and absorbance detection. Specifically, post column addition of potassium iodide followed by detection of triiodide using a uv-vis detector. The systems must meet the requirements for trueness, precision and limit of detection detailed in The Water Supply (Water Quality) Regulations 2018. See Invitation to Tender for further details.

Location

Country

United Kingdom (UK)

Source

Source

Find a Tender Service (UK)

URL

More Details

Record type

Tender

Sector

Water Supply and Storage, Fertilizers, Manufacturing (Industrial), Commercial, Hospital

Article published date

2026-09-21

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender