Amendment 0002 to Solicitation #: 1333MK26Q0038 is to correct the following question from the previous Amendment as follow : Q . What size is the dry well for the Metrix Valve ? A . Thermowell is actually 6 - inches in length for thermostatic assembly part number 50M - 261M - X . All of the other terms and conditi
- Status
- Closed
- Sector
- Airport, Aerospace & Defense, Water Supply and Storage, Oil and Gas, Seaport, Government, Commercial, Automotive, Residential
- Location
- Missouri, United States of America
- Updated
- 3 Nov 2026
- Source
- Missouri Purchasing Group
ConstructChat
Ask ConstructChat about J -- PROVIDE HVAC PLANT REPAIRS TO THE NOAA SHIP PISCES
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | Amendment 0002 to Solicitation #: 1333MK26Q0038 is to correct the following question from the previous Amendment as follow : Q . What size is the dry well for the Metrix Valve ? A . Thermowell is actually 6 - inches in length for thermostatic assembly part number 50M - 261M - X . All of the other terms and conditions remain the sameEnd of Amendment 0002Amendment 0001 to Solicitation #: 1333MK26Q0038 is to provide answers to vendors questions : Q1 . Will the oil pump be provided by the vessel or do we need to quote a new oil pump ? A1 . Oil Pump must be furnished by the contractor - see Paragraph 4 . 1 . 1Q2 . Will refrigerant be supplied by the vessel if the system requires more ? A2 . Supplying all refrigerant is the responsibility of the contractor - see Paragraph 4 . 1 . 2 . For bidding purposes , assume one ( QTY 1 ) 30 - lb cylinder of R - 134 will be required . Q3 . What size is the dry well for the Metrix Valve ? A3 . Dry well is a 3 - inch length probe size . Q4 . How many Domestic and Scientific Refrigeration Units are on board ? A4 . Domestic units : 2 units , Scientific Reefer : 1 unitAll of the other terms and conditions remain the sameEnd of Amendment 0001THIS IS A COMBINED SYNOPSIS / SOLICITATION FOR COMMERCIAL ITEMS PREPARED IN ACCORDANCE WITH THE FORMAT IN FAR SUBPART 12 . 6 , AS SUPPLEMENTED WITH ADDITIONAL INFORMATION INCLUDED IN THIS NOTICE . THIS ANNOUNCEMENT CONSTITUTES THE ONLY SOLICITATION ; QUOTES ARE BEING REQUESTED AND A WRITTEN SOLICITATION WILL NOT BE ISSUED . THIS SYNOPSIS / SOLICITATION 1333MK26Q0038 CONSTITUTES A REQUEST FOR QUOTATION ( RFQ ) AND INCORPORATES PROVISIONS AND CLAUSES IN EFFECT THROUGH FEDERAL ACQUISITION CIRCULAR 2026 - 01 . THE NATIONAL OCEANIC ATMOSPHERIC ADMINISTRATION ( NOAA ), OFFICE OF MARINE & AVIATION OPERATIONS ( OMAO ), NOAA SHIP PISCES REQUEST HVAC PLANT REPAIRS ONBOARD THE SHIP . CLIN DESCRIPTION QUANTITY UNIT PRICE TOTAL PRICE0001 PROVIDE HVAC PLANT REPAIRS ONBOARD THE NOAA SHIP PISCES PER ATTACHED STATEMENT OF WORK . PERIOD OF PERFORMANCE : 3 / 26 / 2026 – 4 / 5 / 2026PLACE OF PERFORMANCE : NOAA SHIP PISCESNAVAL STATION NEWPORT RHODE ISLAND47 CHANDLER STREETNEWPORT , RHODE ISLAND , 08241ADDITIONAL ITEM REQUIREMENTS ( AIR ): THESE ITEMS RELATE TO GROWTH WORK . THE RATES QUOTED WILL BE USED THROUGHOUT THE LIFE OF THE CONTRACT IF GROWTH WORK IS ADDED TO THE SCOPE OF THE CONTRACT [ REFERENCE COMMERCE ACQUISITION REGULATION ( CAR ) CLAUSE 1352 . 271 - 72 ]. IF AIRS ARE ISSUED , THESE ITEMS WILL BE AWARDED AT THE QUANTITIES NEEDED VIA A CONTRACT MODIFICATION . CLIN 0002 GROWTH WORK ** PROVIDE BREAKDOWN , AS FOLLOWS : AIRS / GROWTH HOURLY LABOR RATE ** REGULAR LABOR RATE__________________PER HOUROVERTIME RATE____________________PER HOURHOLIDAY / WEEKEND OVERTIME _________________PER HOUR . THE GOVERNMENT WILL AWARD A FIRM FIXED PRICE CONTRACT BASED ON BEST VALUE TO THE GOVERNMENT : OEM CARRIER TRAINED / CERTIFIED AND / OR PAST EXPERIENCE / PERFORMANCE , AND BEST PRICE . THIS ACQUISITION IS A 100 % SMALL BUSINESS SET ASIDE UNDER THE NAICS CODE 336611 , SHIP BUILDING AND REPAIRING , WITH THE SIZE STANDARD OF 1 , 300 EMPLOYEES AND THE PRODUCT SERVICE CODE IS J020 . PLEASE REVIEW THE ATTACHED RFQ 1333MK26Q0038 AND PROVIDE THE FOLLOWING INFORMATION WITH YOUR OFFER , FAILURE TO PROVIDE THE FOLLOWING DOCUMENTATION MAY BE EXCLUDED FROM CONSIDERATION . 1 . PLEASE PROVIDE NAME , ADDRESS , TELEPHONE NUMBER , SAM UEI , AND THE FIRST PAGE OF YOUR SAM REGISTRATION . 2 . AN ITEMIZED / DETAIL BREAKDOWN COST OF THE QUOTE THAT WILL REFLECT THE ENTIRE PRICE UNDER THIS RFQ . ( THAT WOULD INCLUDE ONLY IF APPLICABLE THE FOLLOWING : PARTS , LABOR , TRAVEL , ETC .). 3 . A COPY OF THE LIABILITY INSURANCE ( PLEASE ENSURE IS UP TO DATE ). 4 . INCLUDE STATEMENT SPECIFYING THE EXTENT OF AGREEMENT WITH ALL TERMS , CONDITIONS , AND PROVISION INCLUDED IN THE RFQ . QUOTES THAT REJECT THE TERMS AND CONDITIONS OF THE RFQ MAY BE EXCLUDED FROM CONSIDERATION . 5 . ACKNOWLEDGEMENT OF SOLICITATION AMENDMENTS ( SF - 30 ) IF ANY . 6 . VENDOR SHALL BE AN AUTHORIZED DEALER , DISTRIBUTOR , OR SERVICE PROVIDER FROM ( CARRIER ) AND PROVIDE AN AUTHORIZED DISTRIBUTOR / VENDOR SERVICE LETTER FROM THE OEM AND / OR PROVIDE OEM CARRIER TRAINED / CERTIFICATIONS . IF THE VENDOR IS NOT AN AUTHORIZED SERVICE PROVIDER OR OEM CARRIER TRAINED / CERTIFIED VENDOR SHALL PROVIDE AT LEAST THREE DETAIL JOBS WITH REFERENCES PERFORMED WITHIN THE PAST THREE YEARS THAT ARE THE SAME OR SIMILAR IN SCOPE SPECIFICALLY WITH DETAILING EXPERIENCE TROUBLESHOOTING / REPAIRING OF FSV CLASS HVAC CHILLED WATER MODEL 30HXS086R - 140 HVAC PLANTS . 7 . VENDOR SHALL PROVIDE A POINT OF CONTACT THAT INCLUDES NAME , TELEPHONE NUMBER , EMAILS , CONTRACT VALUE AND A DETAIL DESCRIPTION OF THE WORK PERFORMED . ALL RESPONSIBLE SOURCES MAY SUBMIT A QUOTATION , WHICH SHALL BE CONSIDERED BY THE AGENCY . QUOTES MUST BE SUBMITTED VIA ELECTRONIC MEANS ( EMAIL ) NO LATER THAN MARCH 20 , 2026 AT 1 : 00 P . M . EASTERN TIME ( ET .) TO ALEXANDER . CANCELA @ NOAA . GOV . THE GOVERNMENT DOES NOT ACCEPT RESPONSIBILITY FOR NON - RECEIPT OF EMAIL . ALL QUESTIONS MUST BE SUBMITTED IN WRITING TO ALEXANDER . CANCELA @ NOAA . GOV BY MARCH 19 , 2026 AT 12 : 00P . M . ET . TELEPHONE INQUIRIES WILL NOT BE HONORED . CONTRACTORS ARE ENCOURAGED TO REGISTER WITH THE HTTPS :// BETA . SAM . GOV / VENDOR NOTIFICATION SERVICE AS WELL AS THE INTERESTED VENDORS LIST FOR THIS ACQUISITION ( SEE APPLICABLE TAB WITHIN HTTPS :// SAM . GOV / WHERE THIS SYNOPSIS / SOLICITATION IS POSTED ). QUOTERS MUST BE REGISTERED IN THE SAM DATABASE TO BE CONSIDERED FOR AWARD . REGISTRATION IS FREE AND CAN BE COMPLETED ON - LINE AT HTTPS :// BETA . SAM . GOV /. FOR CLAUSES AND PROVISIONS PLEASE SEE ATTACHED : 1 . SF1449 1333MK26Q0038 |
Location
Country | United States of America (USA) |
State | Missouri |
Source
Source | Missouri Purchasing Group |
URL |
More Details
Record type | Tender |
Sector | Airport, Aerospace & Defense, Water Supply and Storage, Oil and Gas, Seaport, Government, Commercial, Automotive, Residential |
Article published date | 2026-04-29 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Airport tenders in United States of America
- Fuel Tank Inspection and Repair Services
- Tacoma Narrows Airport TIW Taxiway Relocation Improvements Project
- Cargo Apron Reconstruction and Replacement of Runway 927 with a Taxiway
- Fall Protection for Airport Jet Bridges
- Notice of Intent to Award a NonCompetitive Procurement for Siemens Logistics High Speed Diverters
- This is a Notification Only Continuing OnCall Architecture and Engineering Consulting Services W00486
- Electronic Gate Replacement
- INFORMATION TECHNOLOGY IT CONTINUING CONSULTING SERVICES