Tender
Sources Sought

Sources Sought Purpose The Department of Veterans Affairs, Network Contracting Office (NCO) 6 is seeking qualified contractors capable of installing a chilled-water bypass loop system serving the third-floor laboratory space. This Sources Sought notice is issued for market research and acquisition planning purposes only. It is not a solicitation, request for proposal, invitation for bid, or promis

Status
Prospective
Sector
Residential, Commercial, Water Supply and Storage
Location
Richmond, Virginia, United States of America
Updated
3 Nov 2026
Source
SAM.gov

ConstructChat

Ask ConstructChat about J048--Clinical Lab Bypass Loop System Install

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “J048--Clinical Lab Bypass Loop System Install” is a tender record in Taiyo, linked to the Residential sector. It is issued for works, goods, or services related to Richmond, Virginia, United States of America.

Participants

Not available for this record.

Status

Original status

sources sought

Taiyo status

Prospective

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

Sources Sought Purpose The Department of Veterans Affairs, Network Contracting Office (NCO) 6 is seeking qualified contractors capable of installing a chilled-water bypass loop system serving the third-floor laboratory space. This Sources Sought notice is issued for market research and acquisition planning purposes only. It is not a solicitation, request for proposal, invitation for bid, or promise to award a contract. The VA is seeking responses from qualified small and other-than-small businesses, including firms capable of performing the work. Background The Central VA Healthcare System is requesting a new chiller to be installed on the roof of the third-floor laboratory. However, a chilled-water bypass loop system was not installed as part of the original work. Because the system lacks the required bypass loop, the chiller shuts down after operating for a period of time or upon reaching a predetermined operating condition. These shutdowns result in inadequate cooling and elevated temperatures within the laboratory space. The VA requires the installation of a bypass loop system and integration with the existing chiller, air-handling equipment, and Johnson Controls, Inc. (JCI) building automation/control system. Requested Information Interested firms are invited to submit a capability statement addressing the following: Company name, address, point of contact, telephone number, and email address. Unique Entity ID and CAGE code, if available. Business size and socioeconomic status, including any applicable: Small business status Service-Disabled Veteran-Owned Small Business status Veteran-Owned Small Business Status 8(a) status Woman-Owned Small Business status HUBZone status Confirmation of the firm s ability to perform the work as a prime contractor. Relevant experience installing chilled-water bypass loops, chiller piping systems, HVAC controls, or comparable systems. Experience integrating HVAC equipment with Johnson Controls or similar building automation systems. At least two relevant projects completed within the past five years, including: Customer name Contract or project value Location Dates of performance Description of work performed Point of contact and telephone number or email address Identification of proposed subcontractors and the work they would perform. Applicable licenses, certifications, bonding capacity, and safety qualifications. Any concerns, assumptions, or recommendations regarding the anticipated scope. Indication of whether the firm believes the requirement can be set aside for a particular small-business category. Contracting Specialist: Cedric Frasier Email: cedric.frasier@va.gov Response Due Date: November 2, 2026 @ 4PM ET. The subject line should read: Sources Sought Response Third-Floor Laboratory Chilled-Water Bypass Loop 36C24627Q0088 Important Notice This notice is for market research and acquisition planning only. The Government will not pay for information submitted in response to this notice, nor will it reimburse respondents for any costs associated with preparing or submitting a response. A response to this notice does not constitute an offer and will not be considered a proposal or quotation. The Government is not obligated to issue a solicitation, award a contract, or reimburse respondents for any costs. Respondents will not be notified individually of the results of the market research. Information submitted may be used to determine the appropriate acquisition strategy and solicitation requirements.

Original sector

Construction

Location

Country

United States of America (USA)

State

Virginia

City

Richmond

Source

Source

SAM.gov

URL

More Details

Record type

Tender

Sector

Residential, Commercial, Water Supply and Storage

Article published date

2026-10-27

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender