J059 -- Vertical Transportation Equipment Maintenance Contract Martinsburg Veterans Administration Medical Center ( VAMC ) Source Sought Notice
One of 4,329 tenders Taiyo tracks in West Virginia.
Source: West Virginia Purchasing Group
Sources Sought Notice - Vertical Transportation Equipment Maintenance Contract - Martinsburg Veterans Administration Medical Center ( VAMC ). This is a Sources Sought Notice ; it is not a Request for Quotes or Proposals The Martinsburg VAMC is seeking Vertical Transportation Equipment Maintenance contract . Requirements Contr
- Status
- Closed
- Sector
- Government, Commercial, Automotive, Residential, Hospital
- Location
- West Virginia, United States of America
- Updated
- 3 Nov 2026
- Source
- West Virginia Purchasing Group
ConstructChat
Ask ConstructChat about J059 -- Vertical Transportation Equipment Maintenance Contract Martinsburg Veterans Administration Medical Center ( VAMC ) Source Sought Notice
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | Sources Sought Notice - Vertical Transportation Equipment Maintenance Contract - Martinsburg Veterans Administration Medical Center ( VAMC ). This is a Sources Sought Notice ; it is not a Request for Quotes or Proposals The Martinsburg VAMC is seeking Vertical Transportation Equipment Maintenance contract . Requirements Contractor must provide all management , supervision , labor , parts , material , tools , incidental engineering services , and transportation necessary to perform maintenance , repair , inspection , testing , and component replacement to keep vertical transportation equipment operating as originally specified by equipment manufacturer or modified with the approval of the VA . Contractors , without additional expense to the Government , shall obtain all licenses , permits , and insurance required to perform the work in this statement of work . Contractor shall comply with all applicable federal , state , and local laws . Evidence of insurance , licenses , and permits shall . be provided to the Contracting Officer prior to commencing work . Qualification for elevator mechanics : Contractor is currently engaged in maintenance , repair , inspection , and testing of vertical transportation equipment . Contractors shall have a minimum of five ( 5 ) years of current : ( within the past seven ( 7 ) years ) of successful experience maintaining elevator equipment identica1 or similar to the vertical transportation equipment listed in this contract . Offerors shall submit references for the five ( 5 ) years of experience including names , addresses , and telephone numbers of specific companies and key personnel to contact . The Contractor shall provide a Contract Manager who shall be responsible for the performance of the work . The name of the contract manager and an alternate shall be designated in writing to the CO / COR prior to the contract start date . Changes to personnel shall be submitted to the Government within five ( 5 ) workdays of the changes . The Contract Manager or alternate shall have full authority to act on all contract matters relating to the daily operation of the contract . The Contract Manager or alternate shall be available to speak / meet with the CO / COR within 24 hours of request during normal operating hours , and or within the next business day after Friday or a Federal holiday . Contractor shall provide Elevator Mechanics / Technicians who have completed an Apprenticeship Program and passed the Mechanic / Technician Examination approved and certified by the U . S . Department of Labor . Certified Elevator Mechanics / Technicians shall have technical qualifications of at least five ( 5 ) years of successful experience in the elevator industry . Apprentices shall be actively pursuing Certified Elevator Mechanic / Technician status . Certificates shall be submitted to the CO / COR . All employees of the contractor performing work under this contract at the VAMC for more than forty ( 40 ) hours over contract period shall have completed up to one hour of Infectious Control training provided by the VA . All employees of the contractor shall have completed a 10 hour OSHA Safety Course . Certificates of completion shall be submitted to the CO / COR . The selection , assignment , and management of contractor ' s employees are the responsibility of the Contractor . The Contactor shall not employ any individual identified as a potential threat to the health , safety , security , and general wellbeing , or operation of the VA / VAMC or personnel . The Contractor is fully responsible for the performance and conduct of his / her employees at all times . The Contractor shall not allow any employee to perform work under this contract while under the influence of alcohol , drugs , or any other incapacitating agent . CODES and STANDARDS Publications listed herein form a part of this statement of work . Elevators shall meet the requirements of code editions published by ASME , NFPA , IBC , and adopted by the Department of Veterans Affairs on the date the installation contract was signed or when alterations were performed . Elevator Industry Field Employees Safety Handbook International Building Code ( IBC ) American Society of Mechanical Engineers ( ASME ): A17 . 1 - Safety Code for Elevators and Escalators A17 . 2 Inspector Manuals for Electrical Elevators and Escalators A17 . 3 - Safety Code for Existing Elevators and Escalators A17 . 5 Elevator and Escalator Equipment A17 . 6 Standard for Elevator Suspension , Compensation , and Governors A18 . 1 Safety Standard for Platform Lifts and Stairway Chairlifts QEI - 1 Standard for the Qualification of Elevator Inspections National Fire Protection Association ( NFPA ): NFPA 13 - Standard for the Installation of Sprinkler Systems NFPA 70 National Electrical Code ( NEC ) NFPA 72 National Fire Alarm and Signaling Code NFPA 101 Life Safety Code NFPA 252 Fire Test of Door Assemblies REQUESTED RESPONSES : All responsible vendors and interested parties please respond to this source sought announcement if you can fulfill the requirements . Responses to this source sought shall include the following information : 1 . Business name ( including Unique Entity ID ( SAM . gov ) 2 . Business type , socio - economic status ( e . g ., Veteran - Owned , Woman - Owned , Disadvantaged Small Business , 8 ( a ), etc .), and 3 . Person of contact ( including telephone number & email address ). 4 . Capability statement and summary of previous experience providing these types of services for the Veterans Health Administration or other similar facilities . 5 . Available contract vehicles ( GSA FSS , etc .) for use by Department of VA ( include applicable NAICS ) 6 . Brief Summary of categories of services that your company can / cannot provide . 7 . Certification ( s ) / Licenses for meeting the local requirements to provide these services at the Perry Point , Baltimore and Loch Raven VAMC ( if applicable ). 8 . Confirmation that your organization has the capability & expertise to meet the performance requirements while complying with applicable limitations in subcontracting by responding to the questions below with your response : Do you intend to self - perform this effort ? If you are located outside the immediate area , how will you self - perform ? Or do you intend to subcontract work under this contract ? If you intend to subcontract work under this contract , how will you ensure compliance with the limitations on subcontracting ? The anticipated date of solicitation is February 9th , 2026 , with an expected period of performance starting March 7th , 2026 , to March 6th , 2027 , using NAICS CODE 561210 , Facilities Support Services . Vendors will not receive formal notification or feedback on any information submitted in this Sources Sought Notice . All future proposed submissions and solicitations requirements solicited on a Government Point of Entry ( GPE ) will be evaluated independently of any information submitted in response to this Sources Sought Notice . No vendor will be provided with information on solicitations issued on a Government Point of Entry based on this Sources Sought Notice . Potential Sources shall provide their Capability Statement , and it must be clear , concise , and complete . Interested contractors should respond to this notice via email to Trever . Turcotte @ va . gov and William . Galletta @ va . gov using the subject 36C24526Q0186 - Martinsburg Elevator PM and Repair Contract by Wednesday February 4th 2026 , 09 : 00 am EST . There is no other information available at this time . Responses to this notice may be used in determining an appropriate set - aside . Thank you for your interest . |
Location
Country | United States of America (USA) |
State | West Virginia |
Source
Source | West Virginia Purchasing Group |
URL |
More Details
Record type | Tender |
Sector | Government, Commercial, Automotive, Residential, Hospital |
Article published date | 2026-05-02 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Government tenders in United States of America
- Power Utility Rate Consulting Services for 2021 Electric Rates Study
- RFP - Thurston County Periodic Comprehensive Plan Update
- RFP - Portable Mass Spectrometer Device
- RFP - Developmental Disabilities Department Community Project Grants
- RFP - STEP Tank Pumping
- 8-Inch and 16-Inch Ductile Iron Water Main Replacement on Je...
- 525 Golden Gate Avenue Roof Access and Fall Protection
- San Joaquin Pipeline Valve and Safe Entry Improvements: Phas...
