L7-090 Repair And Liner - Chemical Storage Tanks
Combined synopsis/solicitation · Georgia
Source: SAM.gov
The Contractor shall provide all the tools, parts, materials, equipment, labor, repairs, and travel necessary to perform repairs on the existing Polyvinylidene Flouride (PVDF) L7-090 Liner for the Chemical Storage Tank in Building 20128 and supply one (1) new L7-090 Liner for the Commodities Maintenance Group (CMXG) at Robins Air Force Base (AFB), Georgia. The Contractor shall repair the existing
- Status
- Closed
- Sector
- Chemical (Industrial), Government, Aerospace & Defense, Commercial, Residential, Manufacturing (Industrial)
- Location
- Georgia, United States of America
- Updated
- 3 Nov 2026
- Source
- SAM.gov
ConstructChat
Ask ConstructChat about L7-090 Repair And Liner - Chemical Storage Tanks
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | combined synopsis/solicitation |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | The Contractor shall provide all the tools, parts, materials, equipment, labor, repairs, and travel necessary to perform repairs on the existing Polyvinylidene Flouride (PVDF) L7-090 Liner for the Chemical Storage Tank in Building 20128 and supply one (1) new L7-090 Liner for the Commodities Maintenance Group (CMXG) at Robins Air Force Base (AFB), Georgia. The Contractor shall repair the existing liner in the facility inside of L7-090. The additional spare liner shall be identical in contruction, material, and instrumentation to the existing liner and be stored by CMXG for future use. The Contractor shall provide the following: • Repair of L7-090 Liner on Tank 120 at Building 20128. This will include one (1) technician to facilitate repairs. • 1 each (PVDF) Kynar® Rigid Box Liner to fit CMXG’s existing tank • Approximately 48” x 48” x 72” deep, fabricated from ¼” thick Kynar 2850 Flex sidewalls and rim and 3/8” thick Kynar 2850 Flex bottom. Liner will be fabricated incorporating Patented (#8,133,345) N-FUZE lining technology, utilizing pressure butt-welded vertical joints and extrusion welded sidewall to bottom contruction. The tank shall have one (1) 45 degree corner where CMXG can re-install existing TANKeye Plus Leak Dectection System |
Original sector | Construction |
Location
Country | United States of America (USA) |
State | Georgia |
Source
Source | SAM.gov |
URL |
More Details
Record type | Tender |
Sector | Chemical (Industrial), Government, Aerospace & Defense, Commercial, Residential, Manufacturing (Industrial) |
Article published date | 2026-07-02 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Chemical (Industrial) tenders in United States of America
- 2024 Glass Beads
- Chemical Biological Radiological Nuclear CBRN Respirators and Replacement Filters
- Antiscalant Chemical
- SUPPLY AND DELIVERY OF POLYMER
- Biosolids Digester Facilities Project Request / Notice for P...
- Sunol Valley Water Treatment Plant and Chloramination Facili...
- Sunol Valley Chemical Facility Improvements [BID TABULATION]
- Biosolids Digester Facilities Project - Southeast Water Poll...