Lead Inspection at 7780 Lake Street , Bear Lake
One of 3,321 tenders Taiyo tracks in MITN.
Source: MITN Purchasing Group
Lead - Based Paint Hazards : The purposes of the assessment / inspection are : 1 ) to identify the potential for worker exposure to lead during proposed renovation activities . 2 ) to test paint on surfaces that will be disturbed during the renovation ; and 3 ) to provide that information to contractors , subcontractor
- Status
- Closed
- Sector
- Residential, Road
- Location
- MITN, United States of America
- Updated
- 3 Nov 2026
- Source
- MITN Purchasing Group
ConstructChat
Ask ConstructChat about Lead Inspection at 7780 Lake Street , Bear Lake
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | Lead - Based Paint Hazards : The purposes of the assessment / inspection are : 1 ) to identify the potential for worker exposure to lead during proposed renovation activities . 2 ) to test paint on surfaces that will be disturbed during the renovation ; and 3 ) to provide that information to contractors , subcontractors , federal , state or local agencies , and future occupants . A Lead Inspection is being requested , to be conducted by a certified Lead Inspector / Risk Assessor due to the federal funding received to complete the scope of rehabilitation . Since there is not a residential component to the project , evaluation of “ lead - based paint hazards ” as defined by HUD and EPA such as deteriorated lead - based paint ( LBP ), interior dust - lead hazards , soil lead hazards , chewable surfaces , friction surfaces and impact surfaces are NOT a scope of work required under this RFP . The Assessment / Inspection Process . The process shall include the following activities , as applicable : testing for lead content with the use of an X - ray fluorescence ( XRF ) instrument of all coatings on surfaces to be disturbed during the renovation . In addition , paint chip samples shall be obtained from a select number of major painted surfaces at the inspector ’ s discretion . All practices shall follow , or exceed , the generally accepted practices of the profession . Laboratory Requirements . All laboratories selected for use in the evaluation of lead - based paint shall hold all accreditations , certifications and recognitions needed to conduct lead testing services as governed by regulatory agencies having jurisdiction over such work . At a minimum , the laboratory used by the contractor shall be recognized by the U . S . Environmental Protection Agency ( EPA ) National Lead Laboratory Accreditation Program ( NLLAP ) for the analyses performed under this contract , and shall , for work under this contract , use the same analytical method used for obtaining the most recent NLLAP recognition . Copies of certificates shall be provided with the Respondent ’ s submittal . Identification of Lead - Based Paint . The inspector / risk assessor shall sample all components / surfaces to be disturbed during the renovation with an XRF . In addition , inspector / risk assessor shall sample majorpainted surfaces , and any other surfaces not applicable for XRF testing , through the collection of paint chip samples followed by laboratory analysis |
Location
Country | United States of America (USA) |
State | MITN |
Source
Source | MITN Purchasing Group |
URL |
More Details
Record type | Tender |
Sector | Residential, Road |
Article published date | 2026-05-14 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender