1 AN AUTOMATIC BRINE MAKER SYSTEM must be a Accubrine ® NXT - Gen automated brine maker or equal and make the salt act as a filter bed as the water moves down through to the sump area and filter screen . The system must be capable of producing , at a minimum , two hundred ( 200 ) gallons of brine

Status
Closed
Sector
Advanced Electronics, Steel, Water Supply and Storage, Broadband, Telecommunications
Location
Idaho, United States of America
Updated
3 Nov 2026
Source
Idaho Purchasing Group

ConstructChat

Ask ConstructChat about Liquid Salt Brine Maker

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Liquid Salt Brine Maker” is a tender record in Taiyo, linked to the Advanced Electronics sector. It is issued for works, goods, or services related to Idaho, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

1 AN AUTOMATIC BRINE MAKER SYSTEM must be a Accubrine ® NXT - Gen automated brine maker or equal and make the salt act as a filter bed as the water moves down through to the sump area and filter screen . The system must be capable of producing , at a minimum , two hundred ( 200 ) gallons of brine per minute or six thousand ( 6 , 000 ) gallons of brine per hour ( based on available water supply of six thousand ( 6 , 000 ) gallons per hour and storage tank configuration static discharge of forty - five ( 45 ) feet head pressure ) and at a minimum meet the following . 2 LIST OF MINIMUM REQUIREMENTS FOR THE SALT HOPPER : The salt hopper must have a minimum capacity of four point five ( 4 . 5 ) cubic yards ; The minimum inside dumping width must be no less than one hundred twenty ( 120 ) inches ; The salt hopper must be constructed of sixteen thousand ( 16 , 000 )- pound tensile - strength fiberglass and isophthalic resin with all inside surfaces coated with a ceramic resin zero point zero five zero ( 0 . 050 ) inches thick ; The vessel must have structural integral ribs allowing flex with the salt hopper from full to empty . The salt hopper must be capable of being cleaned via flush components of the unit , and any disassembly of components for cleaning is not acceptable ; Whether full or empty , the salt hopper must be able to be cleaned by opening the sump outlet cap and water flush valves . If the salt hopper is empty , the inside floor panel must have the capability of being removed for cleaning by attached lifting straps or another method allowing easy removal of the inside floor panel ; There must be a fresh water flushing system to force sediment to and out of the sump . All valves , bulkhead fittings , and related components one ( 1 ) inch and larger must be manifold - type fittings ; There must be a pressure transducer connected to the PLC to activate brine pump on and off and water flow into the salt tank . These levels must be adjustable from the HMI interface and adjustable to within one ( 1 )- inch increments and ; The transducer must have an air capillary to the inside of the salt hopper . 3 AUTOMATIC BRINE MAKER PRODUCTION SYSTEM EQUIPMENT 3 . 1 The vessel must have two ( 2 )- inch male cam - lock - type fittings and on / off ball valves for hose connections ( fresh water , brine return , brine outlet to pump ); 3 . 2 There must be reinforced forklift pockets for moving the salt tank and ; 3 . 3 Three hundred four ( 304 ) stainless steel is required for all metallic items , as it is the most corrosion - resistant of the three hundred ( 300 ) series of stainless steel . 4 LIST OF MINIMUM REQUIREMENTS FOR THE CONTROL SYSTEM : 4 . 1 Brine pumped from the salt tank must be monitored for salt concentration by a sensor which must monitor brine temperature and automatically compensate brine concentration accordingly . Any need for an operator to manually test the brine concentration is not acceptable ; 4 . 2 All brine exiting the salt tank must pass over the brine concentration sensor that monitors brine between zero point zero ( 0 . 0 ) and twenty - seven point zero ( 27 . 0 ) percent concentration by weight ; 4 . 3 The system must come complete with the ability to access the HMI ( operator interface ) via the Internet . The operator must be able to view the brine maker ’ s functions remotely ; 4 . 4 The system must include a two hundred fifty - six ( 256 )- color LCD touch - screen display , minimum seven and one - half ( 7 . 5 ) inches diagonal ; 4 . 5 The information on the display screen must include , but not be limited to : 4 . 5 . 1 Actual brine production concentration as a percentage of sodium chloride concentration by weight ; 4 . 5 . 2 Gallons of fresh water used to make brine ;

Location

Country

United States of America (USA)

State

Idaho

Source

Source

Idaho Purchasing Group

URL

More Details

Record type

Tender

Sector

Advanced Electronics, Steel, Water Supply and Storage, Broadband, Telecommunications

Article published date

2026-05-11

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender