Medical Grade Curtains
One of 10,000+ tenders Taiyo tracks in North Carolina.
Source: North Carolina Purchasing Group
This is a Request for Information ( RFI ) – Sought Notice Only . This notice is issued solely for information and planning purposes only . 1 . The US Government will not pay for any information or administrative costs incurred in response to this notice . Submittals will not be returned to the responder ; not
- Status
- Closed
- Sector
- Metal, Aerospace & Defense, Steel, Government, Manufacturing (Industrial), Hospital
- Location
- North Carolina, United States of America
- Updated
- 3 Nov 2026
- Source
- North Carolina Purchasing Group
ConstructChat
Ask ConstructChat about Medical Grade Curtains
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | This is a Request for Information ( RFI ) – Sought Notice Only . This notice is issued solely for information and planning purposes only . 1 . The US Government will not pay for any information or administrative costs incurred in response to this notice . Submittals will not be returned to the responder ; not responding to this notice does not preclude participation in any further RFQ ; IFB or RFP if issued . 2 . The associated North American Industry Classification System ( NAICS ) is 314120 . The business size standard is 750 Employees . All contractors doing business with the Department of Defense shall be registered and approved through the System for Award Management ( SAM ). This is the Official U . S . Government system that consolidates the capabilities of CCR / FedReg , and EPLS . There is no fee to register for this site . Entities may register at no cost directly from this page . The proposed performance start date will be on or about 1 April 2026 . The Solicitation number isW81K0426QA043 . 3 . Note – Prior to award your company shall reflect the NAICS Code 314120 identified on your SAM . If your company is interested in competing on this project , and have services , please submit the following documentation no later than 24 April 2026 , 10 : 00 AM EST , to Cynthia A . Richardson - Rhone and Jason Holck at cynthia . a . richardson - rhone . civ @ health . mil . All questions need to be submitted NLT 22 April 2026 by 10 : 00 AM EST . Your email response shall provide the following : Can you provide the following : Railroaded Cubicle Curtains for Womack Army Medical Center . The curtains will go inside of the patient ’ s room replacing the worn curtains or installing them where needed . The vendor will only supply the curtains . They will be installed by Womack personnel . SalientCharacteristics : Minimum Clinical Performance Requirements - Overall , Curtain length with mesh : To be determined by Contractor based on criteria of 12 ” above finished floor , ( AFF ), allow 56 ” for panel height and 20 ” (+/-) at mesh for a total of 76 ’’ length , with the width of 136 ’’.- Curtain Fullness : Length of track plus 12 % additional fullness - Curtain Heading : Standard track heading ; Color : Gold - Curtain Seams : Flat , ½ ” gauge double needle lock stitch , 100 % mercerized cotton thread - Curtain Hems : Double turned , twin needle stitched , 100 % mercerized cotton thread - Curtain Hem Size : 1 ” Double - stitched bottom and side hem - Fabric Testing : Passes National Fire Prevention Association ( NFPA ) 701 - Mesh : 100 % Nylon ; Color : Gold - Mesh Fabrication : continuous ; “ Z ” folded to the body of the curtain - Mesh opening size : ½ ” aperture - Mesh portion to consist of (+/-) 30 ” of large - scale heavy nylon mesh - Top 1 ¼ ” woven selvage banding shall be folded before final sewing - Double row stitching 7 / 8 ” inch apart shall be used on all banding - Provide beige / aluminum snaps , Dia .: . 5 ”; anodized aluminum or painted white snaps - Snaps located every 4 ” o . C - Privacy curtain fabric panels shall be installed to provide continuous track coverage by overlapping each panel 4 inches and vertical snaps provided for privacy between panels on 8 ” o . C Provide beige / aluminum snaps , Dia .: . 5 ”; anodized aluminum or painted white snaps .- Finished privacy curtain panel size approx . 136 ” w X 74 ” h from bottom of mesh header to finishedlength of panel . Source ConsiderationsFire Safety Compliance - Meet NFPA 701 standardBiomedical Tech ConsiderationsInfection Control : Antimicrobial CurtainsFabric Durability : Able to be laundered at temperatures of 160 degrees maxPlease ensure to address the below : Name of CompanyPoint of contactPhone numberEmail addressIdentify Your Small Business Socio - Economic GroupDUNS number and CAGE Code4 . This requirement No telephonic inquiries will be responded to . A solicitation will be posted within 2 - 3 weeks www . Sam . gov . |
Location
Country | United States of America (USA) |
State | North Carolina |
Source
Source | North Carolina Purchasing Group |
URL |
More Details
Record type | Tender |
Sector | Metal, Aerospace & Defense, Steel, Government, Manufacturing (Industrial), Hospital |
Article published date | 2026-05-05 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Metal tenders in United States of America
- Token Creek Roof Replacements
- HVAC Ice Machine Servicing and Sheet Metal Fabrication
- Jail Courthouse Walkway Project
- RFP 887702021MF Rapid Response Fire Boat for Norfolk FireRescue
- Various Locations Sewer Replacement No. 9 [BID TABULATION]
- Millbrae Warehouse Loading Dock Repair
- Biosolids Digester Facilities - Southeast Treatment Plant T-...
- Electrical (C-10 License), San Francisco, San Mateo, Santa C...
