Military Housing Office Inspection Kits
One of 10,000+ tenders Taiyo tracks in Texas.
Source: SAM.gov
- Binoculars; Quantity = 194 Make/Model: Fujinon 10x50, Steiner 10x50 Military Marine, or equivalent Specifications for "Steinger Military Marine 10x50" (or equal) products: Magnification: 10x Objective Lens Diameter: No less than 50mm Field of View: No less than 327 ft at 1000 yds Focus: Auto Focus System Optics: Fully coated high contrast optics Close Focus: No more than 75 ft IP Distance: 56-7
- Status
- Prospective
- Sector
- Geothermal, Natural Gas, Aerospace & Defense, Government, Commercial, Residential, Manufacturing (Industrial), Water Supply and Storage
- Location
- San Antonio, Texas, United States of America
- Updated
- 3 Nov 2026
- Source
- SAM.gov
ConstructChat
Ask ConstructChat about Military Housing Office Inspection Kits
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | solicitation |
Taiyo status | Prospective |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | 1. Binoculars; Quantity = 194 Make/Model: Fujinon 10x50, Steiner 10x50 Military Marine, or equivalent Specifications for "Steinger Military Marine 10x50" (or equal) products: Magnification: 10x Objective Lens Diameter: No less than 50mm Field of View: No less than 327 ft at 1000 yds Focus: Auto Focus System Optics: Fully coated high contrast optics Close Focus: No more than 75 ft IP Distance: 56-74mm Diopter Range: +/- 5 pdt Luminosity: No less than 25 Durability: Rubber Armoring (Rugged), Waterproof, Housing designed for minimum 8G impact Includes: Objective Covers, Carrying Case, High Contrast, Neck Strap 2. Borescopes; Quantity = 194 Make/Model: Teslong TD-500, Kentfaith Dual -Lens Articulating Borescope, or equivalent Specifications for "Teslong TD-500" (or equal) products: Camera Pixels: 1.0 Megapixel minimum Probe: 2 Way Articulating Probe, 210 deg articulation, diameter no greater than 8.55 mm Field of View: 60 degrees minimum Display: 5 inch minimum, with a screen resolution of at least 854x480 pixels Probe Length: Between 4 to 8 feet Image Resolution: 1920x1080 pixel Durability: IP 67 waterproof 3. Thermal Imager; Quantity = 194 Make/Model: FLIR MR277, Tripplet IRTC550 Thermal Imaging Camera, Protometer BLD5375, Fluke 971 Temperature Humidity Meter, or equivalent 4. Combustible Gas Meters / Combustible Gas Leak Detection; Quantity = 194 Make/Model: TPI 775, BPI Basics Kit, Gas Leak Detector CO Monitor, or equivalent Specifications for "TPI 775 " (or equal) products: Carbon Monoxide Detection: Resolution: 1ppm or lower Range: 0-2,000ppm or larger range Accuracy: +/- 5ppm or 5% of reading (whichever is greater) or better Combustible Gas Leak Detection: Resolution: <50ppm Range: 0 – 50,000 ppm Accuracy: +/- 10% Detectable Gases: Must detect Natural Gas and Propane Alarms: Audible alarm for leaks, adjustable gas upper alarm threshold limit for alarm to permit gas leak isolation 5. GFCI Testers; Quantity = 194 Make/Model: Ideal 61-502 or equivalent Specifications for "Ideal 61-502 120V AC Receptacle Tester" (or equal) product: Certification: UL 1436 and CSA C22.2 no 160 listed Detection Capabilities: Detects open ground, reverse polarity, open hot, open neutral, hot and ground reversed, and hot on neutral with hot open. Functionality: Push to Test function to test operation of GFCI receptacles. 6. Water Pressure Testers; Quantity = 194 Make/Model: Watts 3/4 Inch Plastic Water Pressure Test Guage, or equivalent Specifications for "WATTS ¾ inch Plastic Water Pressure Test Gauge" (or equal) Connection: ¾ inch FIP connection Accuracy: ASME, type B Working Pressure: 0-140 psi Max Pressure: 200 psi 7. IR Thermometers; Quantity = 194 Make/Model: Thermoworks IRT-2 with Probe Kit, or equivalent Specifications for an IR Thermometer and accompanying probe: Product: Ideal 61-502 AC GFCI Receptacle Tester, 120 volt Testing Conditions: open ground, reverse polarity, open hot, open neutral, hot and ground reversed, hot on neutral with open hot Features: GFCI trip test button Certifications: UL 1436 and CSA C22.2 no 160 listed Thermocouple (probe) specifications: Minimum Range: 32 deg F to 149 deg F Accuracy: +/- 0.9 deg F from 32 deg F to 149 deg F Probe Type: Must include a type T straight Penetration Probe, standard tip |
Original sector | Not Identified |
Location
Country | United States of America (USA) |
State | Texas |
City | San Antonio |
Source
Source | SAM.gov |
URL |
More Details
Record type | Tender |
Sector | Geothermal, Natural Gas, Aerospace & Defense, Government, Commercial, Residential, Manufacturing (Industrial), Water Supply and Storage |
Article published date | 2026-06-19 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Geothermal tenders in United States of America
- Biosolids Digester Facilities Project Request / Notice for P...
- Oceanside Water Pollution Control Plant Digester Gas Utiliza...
- MultiSensor HD Thermal Imaging Camera and Helicopter Installation
- ZEBRA ZD421 DIRECT THERMAL DESKTOP PRINTER
- Southeast Treatment Plant (SEP) Biogas Utilization Project
- Induction Mast Standpipe Thermal Spray Repair Services
- Induction Mast Standpipe Thermal Spray Repair Services
- U.S. Department Of Transportation Small Business Innovation Research Fiscal Year 2026 Phase I Solicitation
