logo

Nashville District - Janus Low Pressure Carbon Dioxide Refrigerated Storage Units

One of 10,000+ tenders Taiyo tracks in Tennessee.

Source: SAM.gov

Tender
Special Notice

THIS IS A NOTIFICATION OF INTENT TO AWARD A BRAND NAME SPECIFICATION IN A FUTURE CONTRACT FOR CORDELL HULL AND DALE HOLLOW - U.S. ARMY CORPS OF ENGINEERS – NASHVILLE DISTRICT’S NOTICE OF INTENT TO INCLUDE BRAND NAME SPECIFICATION IN A FUTURE CONTRACT FOR SUPPLY AND DELIVERY OF ONE (1) 4-TON AND ONE (1) 6-TON JANUS LOW PRESSURE CARBON DIOXIDE REFRIGERATED STORAGE UNITS – SOLICITATION W912P526QA***

Status
Prospective
Sector
Commercial, Aerospace & Defense, Government, Power Generation (CCGT), Residential
Location
Carthage, Tennessee, United States of America
Updated
3 Nov 2026
Source
SAM.gov

ConstructChat

Ask ConstructChat about Nashville District - Janus Low Pressure Carbon Dioxide Refrigerated Storage Units

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Nashville District - Janus Low Pressure Carbon Dioxide Refrigerated Storage Units” is a tender record in Taiyo, linked to the Commercial sector. It is issued for works, goods, or services related to Carthage, Tennessee, United States of America.

Participants

Not available for this record.

Status

Original status

special notice

Taiyo status

Prospective

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

THIS IS A NOTIFICATION OF INTENT TO AWARD A BRAND NAME SPECIFICATION IN A FUTURE CONTRACT FOR CORDELL HULL AND DALE HOLLOW - U.S. ARMY CORPS OF ENGINEERS – NASHVILLE DISTRICT’S NOTICE OF INTENT TO INCLUDE BRAND NAME SPECIFICATION IN A FUTURE CONTRACT FOR SUPPLY AND DELIVERY OF ONE (1) 4-TON AND ONE (1) 6-TON JANUS LOW PRESSURE CARBON DIOXIDE REFRIGERATED STORAGE UNITS – SOLICITATION W912P526QA*** The U.S. Army Corps of Engineers Nashville District will be soliciting a sole source quote for a Single Award Firm Fixed-Price supply contract to The Hiller Companies LLC for the supply and delivery of one (1) 4-Ton Janus Fire Systems® Low Pressure Carbon Dioxide Refrigerated Storage Units with the options to purchase one (1) additional 6-ton tank and two (2) additional 4-ton tanks. The Four-Ton Low Pressure Carbon Dioxide Storage Tank shall be designed to work within the existing footprint of the previous 3.75-ton Ansul tank. The new storage tank must be fitted to work and not compromise the integrity of the fire suppression system such as the inlet values, pressure switches and controls, outlet valves, & voltages. Dale Hollow Power Plant staff will remove the existing 3.75-Ton Ansul Low Pressure Carbon Dioxide Refrigerated Storage Unit, disconnect piping, and prepare the area for the new footprint of the tank. (Optional) Cordell Hull Power Plant staff will remove the existing 6-Ton Ansul Low Pressure Carbon Dioxide Refrigerated Storage Unit, disconnect piping, and prepare the area for the new footprint of the tank. (Optional) Wolf Creek Power Plant staff will remove the existing 4-Ton Ansul Low Pressure Carbon Dioxide Refrigerated Storage Unit, disconnect piping, and prepare the area for the new footprint of the tank. (Optional) Laurel Power Plant staff will remove the existing 4-Ton Ansul Low Pressure Carbon Dioxide Refrigerated Storage Unit, disconnect piping, and prepare the area for the new footprint of the tank. For the purposes described herein, the USACE Nashville District intends to issue a sole source solicitation that will include the brand name items listed below: Manufacturer: Janus Fire Systems Quantity: 2 Items: 4-Ton and 6-Ton Janus Low Pressure Carbon Dioxide Storage Tanks The ANSI, ASME, OSHA, and EM385 standards listed below must be met for technical acceptance. A Voltage Requirement A1. 460V, 3 phase, 60HZ B Pressure requirements and Valves B1. Pressure switch (inside) B2. Pressure and liquid level gauges B3. Bleeder valve(s) B5. Safety Relief valve B7. Ball valve (manual limit switch, ½”) B8. Pressure regulator C Other C1. 6” x 4” reducer flange C2. Commercial grade scroll compressor with R454A This Notice of Intent is not a request for competitive quotes. All responsible sources may identify their interest and submit clearly articulated product information. Product information provided will be considered solely at the discretion of the Government. The proposed contract action is for supply for which the Government intends to solicit and negotiate with only one source under the authority of Revolutionary Federal Acquistion Regulation Overhaul (RFO) 12.201-1. Interested persons may identify their interest and capability to respond to the requirement or submit proposals. Responses must be received by July 31, 2026, at 1:00PM, Central Daylight Time to be considered. A determination by the Government not to compete with this proposed contract based upon responses to this notice is solely within the discretion of the Government. Information received will normally be considered solely for the purpose of determining whether to conduct a competitive procurement. The Government will not be responsible for any cost incurred in preparation of your response. Submit a response and questions to this notice to, Contract Specialist Jamie Lynn Barnes: Jamie.L.Barnes@usace.army.mil. The posting of this Notice satisfies the provisions set forth in Revolutionary FAR Overhaul 5.101.

Original sector

Construction

Location

Country

United States of America (USA)

State

Tennessee

City

Carthage

Source

Source

SAM.gov

URL

More Details

Record type

Tender

Sector

Commercial, Aerospace & Defense, Government, Power Generation (CCGT), Residential

Article published date

2026-07-25

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender