Network Backbone Iquitos
Sector: Manufacturing (Industrial) • Location: Peru
Source: SAM.gov
Specifications NAMRU SOUTH will follow the Defense Health Agency (DHA)’s technical guidance and security measures to ensure cybersecurity standards are sustained in this network. Therefore, the models and brand selected are based on existing DHA backbone in the Lima MEDCOI network. Selected brands: •CISCO Selected models: •Core switches: Catalyst 9500 •Edge switches: Catalyst 9300 •Servers Farm sw
- Status
- Prospective
- Sector
- Manufacturing (Industrial), Power Generation (CCGT), Residential, Aerospace & Defense, Hospital, Commercial, Raw Materials
- Location
- Peru
- Updated
- 3 Nov 2026
- Source
- SAM.gov
ConstructChat
Ask ConstructChat about Network Backbone Iquitos
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | solicitation |
Taiyo status | Prospective |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | Specifications NAMRU SOUTH will follow the Defense Health Agency (DHA)’s technical guidance and security measures to ensure cybersecurity standards are sustained in this network. Therefore, the models and brand selected are based on existing DHA backbone in the Lima MEDCOI network. Selected brands: •CISCO Selected models: •Core switches: Catalyst 9500 •Edge switches: Catalyst 9300 •Servers Farm switches: Catalyst 9300 The equipment must meet the following minimum requirements: •Core switches o Qty = 02, Cisco Catalyst 9500 24-port 10Gig (Mfr Part # C9500-24Y4C-E) o Qty = 02, DNA Essentials 3 Year License (Mfr Part# C9500-DNA-L-E-3Y) o Qty = 2, Redundant (x2) 950W power supply (Mfr Part # PWR-C4-950WAC-R/2) o Qty = 02, SFP multimode FO 10GB (Mfr Part # SFP-10G-SR++=) oQty = 02, FO Patch cord LC-LC OM3/OM4 01 o Qty = 02, Cisco Cable (Mfr Part # QSFP-H40G-CU1M | StackWise Virtual) o Qty = 02, Cisco Cable (Mfr Part # SFP-H10GB-CU1M) o Qty = 02, Cisco Cable (Mfr Part # SFP-H10GB-CU3M) o Qty = 02, Transceiver module Cisco (Mfr Part # SFP-10G-T-X) • Edge switches building 1 o Qty = 03, Cisco Catalyst 9300 48-port PoE 10Gig Ethernet (Mfr Part # C9300-48P-E) o Qty = 03, C9300 DNA Essentials, 48-port - 3 Year Term License (Mfr Part # C9300-DNA-E-48-3Y) o Qty = 3, Redundant (x2) 715W power supply (Mfr Part # PWR-C1-715WAC-P/2) o Qty = 02, Catalyst 9300 8x 10GE Network module (Mfr Part # C9300-NM-8X) o Qty = 02, stacking cable (Mfr Part # STACK-T1-50CM=) •Servers Farm switches building 1 o Qty = 02, Cisco Catalyst 9300 24-port PoE 10Gig Ethernet (Mfr Part # C9300-24P-E) o Qty = 02, C9300 DNA Essentials, 24-Port, 3 Year Term License (Mfr Part # C9300-DNA-E-24-3Y) o Qty = 2, Redundant (x2) 715W power supply (Mfr Part # PWR-C1-715WAC-P/2) o Qty = 02, Catalyst 9300 8x 10GE Network module (Mfr Part # C9300-NM-8X) o Qty = 01, stacking cable (Mfr Part # STACK-T1-50CM=) •Edge switches building 2 (Entomology) o Qty = 02, Cisco Catalyst 9300 24-port PoE 10Gig Ethernet (Mfr Part # C9300-24P-E) o Qty = 02, C9300 DNA Essentials, 24-Port, 3 Year Term License (Mfr Part # C9300-DNA-E-24-3Y) o Qty = 2, Redundant (x2) 715W power supply (Mfr Part # PWR-C1-715WAC-P/2) o Qty = 02, Catalyst 9300 8x 10GE Network module (Mfr Part # C9300-NM-8X) o Qty = 02, SFP multimode FO modules 10GB (Mfr Part # SFP-10G-SR++=) o Qty = 01, stacking cable (Mfr Part # STACK-T1-50CM=) oQty = 02, FO Patch cord LC-LC OM3/OM4 01 •Edge switch Freezers Room o Qty = 01, Cisco Catalyst 9300 24-port PoE 10Gig Ethernet (Mfr Part # C9300-24P-E) Qty = 01, C9300 DNA Essentials, 24-Port, 3 Year Term License (Mfr Part # C9300-DNA-E-24-3Y) o Qty = 1, Redundant (x2) 715W power supply (Mfr Part # PWR-C1-715WAC-P) o Qty = 01, Catalyst 9300 8x 10GE Network module (Mfr Part # C9300-NM-8X) o Qty = 01, SFP multimode FO modules 10GB (Mfr Part # SFP-10G-SR++=) oQty = 01, FO Patch cord LC-LC OM3/OM4 01 |
Original sector | Not Identified |
Location
Country | Peru |
Source
Source | SAM.gov |
URL |
More Details
Record type | Tender |
Sector | Manufacturing (Industrial), Power Generation (CCGT), Residential, Aerospace & Defense, Hospital, Commercial, Raw Materials |
Article published date | 2026-09-02 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Manufacturing (Industrial) tenders in Peru
- Rfq -19Pe5026Q0014 - Gsomp - New Vehicles For Replacement
- Rfq -19Pe5026Q0014 - Gsomp - New Vehicles For Replacement
- Callao, Peru Infrastructure Modernization - U.S. Army Corps Of Engineers (Usace) – Latin America And Caribbean District (Saa)
- Callao, Peru Infrastructure Modernization - U.S. Army Corps Of Engineers (Usace) – Latin America And Caribbean District (Saa)
- Acquisition Of Wall-Mounted Inverter Split Air Conditioning Units
- 81322574-Acelerando la transición hacia la economía circular, la gestión de los residuos y las tecnologías neutras en carbono
- Rfq 19Pe5026Q0040 - Corrective Maintenance Of Generators
- Sv26.2 (Peru) Bottled Water
