logo

Nitrogen And Dry-Air Generator For Lc-Ms Applications

The scope, dates and status of this tender. A free account opens every field.

Source: SAM.gov

Tender
Combined Synopsis/Solicitation

The Naval Medical Research Command (NMRC) intends to award a contract resulting from this notice to the responsible offeror. All offers must have a Cage Code and a Unique Entity Identification Number.This is being issued on an unrestricted basis to allow for vendors to provide a quote on Equipment Listed in the attached Solicitation (RFQ). The associated NAICS code is 334516. Offerors must also be

Status
Prospective
Sector
Aerospace & Defense, Oil and Gas, Power Generation (CCGT), Fertilizers, Commercial, Residential, Manufacturing (Industrial), Hospital
Location
Wright Patterson AFB, Ohio, United States of America
Updated
3 Nov 2026
Source
SAM.gov

ConstructChat

Ask ConstructChat about Nitrogen And Dry-Air Generator For Lc-Ms Applications

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Nitrogen And Dry-Air Generator For Lc-Ms Applications” is a tender record in Taiyo, linked to the Aerospace & Defense sector. It is issued for works, goods, or services related to Wright Patterson AFB, Ohio, United States of America.

Participants

Not available for this record.

Status

Original status

combined synopsis/solicitation

Taiyo status

Prospective

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

The Naval Medical Research Command (NMRC) intends to award a contract resulting from this notice to the responsible offeror. All offers must have a Cage Code and a Unique Entity Identification Number.This is being issued on an unrestricted basis to allow for vendors to provide a quote on Equipment Listed in the attached Solicitation (RFQ). The associated NAICS code is 334516. Offerors must also be registered in Systems for Award Management (SAM) at www.sam.gov per FAR 52.212.1 lack of registration in SAM will qualify contractor as ineligible for award. All responsible sources may submit a quotation in response to this notice which shall be considered. The solicitation is being issued as a Request for Quote (RFQ) for a firm fixed type of contract based on the Lowest Price Technically Acceptable. a. The Naval Medical Research Unit Dayton (NAMRU-Dayton) has a requirement for the procurement of one (1) LNI Swissgas NGA CASTORE XL 40.40 Membrane Nitrogen Generator (Part Number: 6920.70.41) to support analytical testing operations in the laboratory. This equipment provides a continuous, high-purity nitrogen gas stream, which is critical for the operation of laboratory analytical instruments, specifically Liquid Chromatography-Mass Spectrometry (LC-MS) systems. b. This generator utilizes specialized membrane technology to separate nitrogen from compressed air. It must deliver a flow rate and purity profile that match the exact requirements of the command's existing mass spectrometers. Deviation from these parameters can cause signal instability, degrade detection limits, void instrument warranties, and lead to costly downtime. **SALIENT CHARACTERISTICS** Nitrogen and dry-air generator for LC-MS applications, LNI Swissgas NGA CASTORE XL iQ 40.40 or equal. Offered system shall be a single, self-contained laboratory gas generator with integrated oil-less compressor and shall not require facility compressed air for normal operation. The system shall provide simultaneous nitrogen and dry-air outputs meeting the following minimum requirements: 1. Nitrogen output: minimum 40 L/min, LCMS-grade nitrogen, purity up to 99.9% or documented equivalent suitable for LC-MS operation. 2. Nitrogen outlet pressure: minimum 8 bar / 116 psi for 220–240 VAC configuration, or minimum 7.5 bar / 108 psi if universal 115–240 VAC configuration is required. 3. Dry-air output: minimum 40 L/min. 4. Dry-air outlet pressure: minimum 8 bar / 116 psi for 220–240 VAC configuration, or minimum 7.5 bar / 108 psi if universal 115–240 VAC configuration is required. 5. Dry-air dew point: ? -40°C atmospheric dew point. 6. Operating noise: ?50 dB(A). 7. Unit footprint: not greater than approximately 59 cm W × 92 cm D × 73 cm H. 8. Controls and monitoring: local touchscreen or equivalent user interface showing system status, pressure/status diagnostics, alarms or pre-alarms; remote start/stop or status monitoring capability via RS485, RS232, digital I/O, Ethernet, or equivalent. 9. Electrical: maximum power draw not to exceed 2.0 kW for 220–240 VAC or 1.7 kW for 115–240 VAC full-range configuration. 10. Integrated or directly compatible UHP nitrogen output capable of at least 200 cc/min at ?99.9999% nitrogen purity, without reducing the main nitrogen/dry-air outputs below required values. 11. Integrated scroll compressor with variable speed technology to preserve power consumption and reduce wear on the compressor system which extends the maintenance interval on the compressor. **WARRANTY** LIMITED WARRANTY - GAS GENERATION SYSTEMS; CALIBRATORS, MIXERS AND SENSORS APPLICABILITY – This warranty is applicable to the forty-eight contiguous United States and Canada only. LNI SWISSGAS US LLC (LNI) warrants that the ITEMS LISTED BELOW shall be free from defects in material and workmanship for the period of time stated below. GAS GENERATION SYSTEMS: Fifteen (15) months from shipment ----------------------------------Added Information----------------------------- **ASSEMBLY / SETUP REQUIRED?** YES **DELIVERABLES** NGA CASTORE XL 40.40 - 6920.70.41 NG(A) CASTORE XS/XL INSTALLATION KIT - 6950.92.061 NG CASTORE XL FILTER ELEMENTS - 6930.00.141 ONSITE STARTUP AND TRAINING - 7000.01.100

Original sector

Not Identified

Location

Country

United States of America (USA)

State

Ohio

City

Wright Patterson AFB

Source

Source

SAM.gov

URL

More Details

Record type

Tender

Sector

Aerospace & Defense, Oil and Gas, Power Generation (CCGT), Fertilizers, Commercial, Residential, Manufacturing (Industrial), Hospital

Article published date

2026-07-02

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender