Notice Of Intent - Sole Source Johnson Controls Electronic Security System For The Chilled Water Plant Replacement And Utility Upgrades Project At The Va West Haven Campus
Sector: Water Supply and Storage • Location: West Haven, Connecticut, United States of America
Source: SAM.gov
Under the authority of FAR 6.103-1, the U.S. Army Corps of Engineers intends to require, on a sole source basis, a brand name requirement for the Johnson Controls systems in the Chilled Water Plant Replacement and Utility Upgrades Project at the VA West Haven Campus. The security system includes access control card readers, door contacts, controllers, motion sensors, Video Surveillance camera, DVR
- Status
- Closed
- Sector
- Water Supply and Storage, Aerospace & Defense, Data Center, Power Generation (CCGT), Power Transmission, Residential, Commercial, Government
- Location
- West Haven, Connecticut, United States of America
- Updated
- 3 Nov 2026
- Source
- SAM.gov
ConstructChat
Ask ConstructChat about Notice Of Intent - Sole Source Johnson Controls Electronic Security System For The Chilled Water Plant Replacement And Utility Upgrades Project At The Va West Haven Campus
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | special notice |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | Under the authority of FAR 6.103-1, the U.S. Army Corps of Engineers intends to require, on a sole source basis, a brand name requirement for the Johnson Controls systems in the Chilled Water Plant Replacement and Utility Upgrades Project at the VA West Haven Campus. The security system includes access control card readers, door contacts, controllers, motion sensors, Video Surveillance camera, DVRs, and duress buttons. The current security system has servers in the data center and control panels/power supplies in the local Telecommunications Rooms (TR’s). The current security system is a Johnson Controls system throughout the campus. The system is monitored in the Security Control Center. The security system needs to communicate throughout the facility as the system is monitored in the security control center. The system will need to have full integration for this single point monitoring to be achieved. Camera, card readers, motion sensors and duress buttons will need to be fully integrated into the existing system to provide the monitoring required by the VA. Security Systems are proprietary systems that do not talk to each other. Having different security systems in different areas risks the health and safety of patients and staff at VA West Haven. The only way to provide full integration and single point monitoring is to provide a system that is comprised of one manufacturer. THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE PROPOSALS. It is a market research tool being used to determine the availability of other qualified sources that can meet the requirements identified above and inherent with the referenced Johnson Controls system. The Government is not obligated to and will not pay for any information received from potential sources as a result of this notice of intent. All responses received within 15 days of the posting of this notice of intent will be considered by the Government. A determination by the Government to require the brand name for the Johnson Controls system for the VA West Haven procurement based on this notice is solely within the discretion of the Government. Information received will normally be considered solely for the purposes of determine whether to allow alternate system manufacturers. Submit responses within 15 days of the posting of this notice of intent via email to: tyler.s.maryak@usace.army.mil and CC erin.e.bradley@usace.army.mil (list "W912WJ26X1B68 – JCI ESS " in the subject line of the email). |
Original sector | Not Identified |
Location
Country | United States of America (USA) |
State | Connecticut |
City | West Haven |
Source
Source | SAM.gov |
URL |
More Details
Record type | Tender |
Sector | Water Supply and Storage, Aerospace & Defense, Data Center, Power Generation (CCGT), Power Transmission, Residential, Commercial, Government |
Article published date | 2026-02-05 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Water Supply and Storage tenders in United States of America
- RFP - Thurston County Lake Management Districts Submerged Aquatic Vegetation Control
- Coatings for Wet Well and Manholes
- Sole Source for Wedeco UV BulbsBallets
- Security Hardware Services
- Chambers Creek Regional Wastewater Treatment Plant BNR Aeration Basin Airflow Meters
- Se Dixie Highway County Road A1A Utility Relocation Project
- UNPAINTED SNOW FENCE AND DUNE GRASS NO II
- PreQualification of Bidders for Chaboya Improvements
