OUTFITTING TWO ( 2 ) 2026 FORD SUPER DUTY F - 250 XL
Bids closed Apr 2026 · California · Last reported Apr 2026
Source: California Purchasing Group
THE COUNTY OF SAN DIEGO IS SEEKING QUOTES FROM QUALIFIED FIRMS ( OFFERORS ) TO OUTFIT TWO ( 2 ) 2026 FORD SUPER DUTY F - 250 XL SUPERCAB 4X4 164 SRW . Outfitting Requirements 2 . 1 . Construction of Unit ( Diagram shown in Sections 2 . 1 . 12 and 2 . 1 . 13 ) 2 . 1 . 1 . Reinforced One - Piece Molded Fiberglass Construc
- Status
- Closed
- Sector
- Metal, Energy Storage, Steel, Telecommunications
- Location
- California, United States of America
- Updated
- 3 Nov 2026
- Source
- California Purchasing Group
ConstructChat
Ask ConstructChat about OUTFITTING TWO ( 2 ) 2026 FORD SUPER DUTY F - 250 XL
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | THE COUNTY OF SAN DIEGO IS SEEKING QUOTES FROM QUALIFIED FIRMS ( OFFERORS ) TO OUTFIT TWO ( 2 ) 2026 FORD SUPER DUTY F - 250 XL SUPERCAB 4X4 164 SRW . Outfitting Requirements 2 . 1 . Construction of Unit ( Diagram shown in Sections 2 . 1 . 12 and 2 . 1 . 13 ) 2 . 1 . 1 . Reinforced One - Piece Molded Fiberglass Construction with a bright white gel coat high gloss exterior finish . Material shall not rust or corrode and steel components are glassed in minimizing exposure to the elements . 2 . 1 . 2 . Body Dimensions Approx : 78 " Wide x 45 " High x 100 " Long . 2 . 1 . 3 . Two ( 2 ) 8 ” or larger diameter PVC catch pole holder mounted on each end of the rear step bumper . Steel tube frame lines interior around the entire bottom of the unit with cross members to provide a solid mounting structure . 2 . 1 . 4 . Installation : Mounts easily to truck frame with bolts using 5 " mounting plates previously mounted to cross members . Units are easily transferred from one vehicle to another . 2 . 1 . 5 . Under Structure : 2 . 1 . 5 . 1 . Framed with 1 . 5 " x 2 " 14 - gauge high strength tubular steel on all sides with two 2 " x 3 " 11 - gauge high strength tubular cross members . 2 . 1 . 5 . 2 . Four 5 " x 4 " x . 375 " solid steel angle mounts are installed for easy mounting on the vehicle frame using grade 8 bolts . 2 . 1 . 5 . 3 . All steel is completely sealed in fiberglass to minimize exposure to the elements and eliminate deterioration . 2 . 1 . 5 . 4 . Rear Bumper : Steel step bumper with tread plate top , powder coated black . 2 . 1 . 6 . Floor : 2 . 1 . 6 . 1 . Constructed using a 1 " foam composite molded and sealed into the unit with two layers of 1 . 5 oz fiberglass mat . 2 . 1 . 6 . 2 . Floors have a . 75 " recess creating a trough under the unit with individual drain capabilities . And the floor is sloped in so the drainage system directs flow into the trough under the unit keeping compartment floors dry and clean . 2 . 1 . 6 . 3 . The undercarriage is then sealed with resin which provides maximum insulation preventing heat from rising through the floor . 2 . 1 . 7 . Compartments : 2 . 1 . 7 . 1 . Walls and ceilings are gel coat sealed and webbed to provide a smooth , easy to clean finish in the compartments . 2 . 1 . 7 . 2 . Front compartment approximate size : 78 ” Wide x 36 ” High x 30 ” Deep - hinged centered door to open both ways 2 . 1 . 7 . 3 . Rear compartment approximate size : 38 " Wide x 36 " High x 30 " Deep 2 . 1 . 8 . Doors : 2 . 1 . 8 . 1 . Doors are constructed of fiberglass with a bright white gel coat finish on the interior and exterior panels . 2 . 1 . 8 . 2 . The outside dimensions of the door are approximately 29 5 / 8 " high x 24 ” wide . 2 . 1 . 8 . 3 . The exterior panel of the door has ( 5 ) five large louver style vents molded into the fiberglass . 2 . 1 . 8 . 4 . The louver openings provide ample air flow to exchange air inside the compartments when operating with forced air ventilation . Interior door panel has a stainless - steel circular vent that can be opened and closed to control air flow . 2 . 1 . 8 . 5 . A stainless steel continuous hinge { 1 . 5 ") ( 20 Gauge ) connects the door to the fiberglass body and doors are hinged toward the front . Aluminum drip shields are placed over all doors . All keyed alike stainless steel recessed folding ' T ' latch locking handle is used . 2 . 1 . 9 . Interior Safety Door Stainless steel ( set of 6 ): 2 . 1 . 9 . 1 . Heavy duty wire interior safety door with an arm and catch pole opening on the latch side . Door is constructed of 3 / 8 " frame and 3 / 8 " horizontal rods with 1 / 4 " vertical rods welded at all intersections . 2 . 1 . 9 . 2 . A heavy duty½ " spring loaded bolt latch is used to provide a positive latching system and the door is mounted with stainless steel hinges . 2 . 1 . 9 . 3 . The interior safety door is installed inside the outer door to keep the animal secured in the compartment when the outer door is opened protecting the operator and allowing full vision of the compartment . 2 . 1 . 9 . 4 . Powder coated black finish or in Stainless Steel . 2 . 1 . 10 . Roof : 2 . 1 . 10 . 1 . Roof is backed by . 375 " dense composite board and 1 . 5 oz fiberglass mat that is completely glassed in providing maximum insulation and strength . 2 . 1 . 10 . 2 . Roof of the compartments are gel coat sealed and webbed . 2 . 1 . 10 . 3 . Roof has a 200 lb . per square foot rating to prevent malforming . 2 . 1 . 11 . Wiring : 2 . 1 . 11 . 1 . All wiring is color - coded , run - in conduit and glassed in so the animals cannot get to the wires . 2 . 1 . 11 . 2 . Wiring shall be easily accessed in junction boxes for future modifications or add on optional equipment installations . 2 . 1 . 11 . 3 . All under hood , associated wiring and cabling must be neatly routed , wire loom or greater protected , securely fastened , with no severe angles of cable mounting . 2 . 1 . 11 . 4 . Hi amp waterproof circuit breakers will not be mounted directly to the battery unless no other mounting option is available . 2 . 1 . 11 . 5 . A separate mount plate away from the vehicle battery is desired and not mounted directly above the vehicle battery . 2 . 1 . 11 . 6 . The contractor shall supply a CAD drawing or similar design with their complete quote . |
Location
Country | United States of America (USA) |
State | California |
Source
Source | California Purchasing Group |
URL |
More Details
Record type | Tender |
Sector | Metal, Energy Storage, Steel, Telecommunications |
Article published date | 2026-05-10 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Metal tenders in United States of America
- Token Creek Roof Replacements
- HVAC Ice Machine Servicing and Sheet Metal Fabrication
- Jail Courthouse Walkway Project
- RFP 887702021MF Rapid Response Fire Boat for Norfolk FireRescue
- Various Locations Sewer Replacement No. 9 [BID TABULATION]
- Millbrae Warehouse Loading Dock Repair
- Biosolids Digester Facilities - Southeast Treatment Plant T-...
- Electrical (C-10 License), San Francisco, San Mateo, Santa C...
