logo

Pinson Dr ., Cut - Off Rd ., and Patterson Drive Water Main Replacement

The scope, dates and status of this tender. A free account opens every field.

Source: Georgia Purchasing Group

Tender
Closed

The Project consists of the following major elements of work : replacement of an existing 2 - inch water line with 4 , 099 ft . of 8 - inch DIP water line . The existing water system will remain operational until installation and testing of the new waterline is complete and approved . Three wet - taps are req

Status
Closed
Sector
Road, Water Supply and Storage
Location
Georgia, United States of America
Updated
3 Nov 2026
Source
Georgia Purchasing Group

ConstructChat

Ask ConstructChat about Pinson Dr ., Cut - Off Rd ., and Patterson Drive Water Main Replacement

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Pinson Dr ., Cut - Off Rd ., and Patterson Drive Water Main Replacement” is a tender record in Taiyo, linked to the Road sector. It is issued for works, goods, or services related to Georgia, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

The Project consists of the following major elements of work : replacement of an existing 2 - inch water line with 4 , 099 ft . of 8 - inch DIP water line . The existing water system will remain operational until installation and testing of the new waterline is complete and approved . Three wet - taps are required and one cut - in connection at the intersection of Patterson and Cut - off Roads which will effectively “ loop ” the distribution system with existing mains . Approximately , 1 , 950 lineal feet of trenching through improved hard surfaces is required including replacement of said surface . The remainder of the proposed waterline is outside of existing roadways . There are numerous instances of work near existing gas lines that require minimum horizontal separation , vertical clearance , and polywrapping of new water lines . Locations of said gas lines shall be verified by potholes by the Contractor . The project disturbs approximately 0 . 90 acres within the Nancy Creek Tributary requiring ES & PC best management practices

Location

Country

United States of America (USA)

State

Georgia

Source

Source

Georgia Purchasing Group

URL

More Details

Record type

Tender

Sector

Road, Water Supply and Storage

Article published date

2026-04-29

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender