PM FOR INSPECTION & TESTING FOR FIRE ALARM SYSTEM ( S )

The scope, dates and status of this tender. A free account opens every field.

Source: Indiana Purchasing Group

Tender
Closed

INSPECTION & TESTING SPECIFICATION FIRE ALARM SYSTEM ( S ) 1 . 01 Scope of Work A . The Contractor must be an authorized Notifier Engineered Systems Distributor with NESCO affiliation to provide on a quarterly basis , all labor and materiel and supervision for a preventative maintenance service as specified herein

Status
Closed
Location
Indiana, United States of America
Updated
3 Nov 2026
Source
Indiana Purchasing Group

ConstructChat

Ask ConstructChat about PM FOR INSPECTION & TESTING FOR FIRE ALARM SYSTEM ( S )

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “PM FOR INSPECTION & TESTING FOR FIRE ALARM SYSTEM ( S )” is a tender record in Taiyo. It is issued for works, goods, or services related to Indiana, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

INSPECTION & TESTING SPECIFICATION FIRE ALARM SYSTEM ( S ) 1 . 01 Scope of Work A . The Contractor must be an authorized Notifier Engineered Systems Distributor with NESCO affiliation to provide on a quarterly basis , all labor and materiel and supervision for a preventative maintenance service as specified herein for Fire Alarm Systems . a . The term of this contract is to for 730 days ( 2 Years ) and to cover all required testing and inspections during that time period as required below . b . Work shall be bid as a 2 - year lump sum . c . Invoices permitted quarterly upon completion of work for that quarter . d . Work shall include providing approved Emergency Services at an additional charge to the contract . C . The Contractor shall furnish all labor , materials , and supervision required to determine the operational status of each device of the existing Fire Alarm System ( s ). Inspection & Testing service procedures provided by contractor shall conform to NFPA standards as adopted by 675 of the Indiana Administrative Code . D . The minimum number of planned inspections shall be two ( 2 ) times per fiscal year spaced approximately 180 days apart and shall conform to required testing frequencies as tabulated within NFPA 72 for each fire alarm component type . The first Inspection & Test cycle shall be performed upon successfully being awarded the contract . E . Each Inspection & Test site visit shall be prescheduled with the Physical Plant Director at least 72 hours prior to arrival of scheduled visit and directed from a maintenance program initiated and maintained by the Contractor . The program shall be either computer directed or manually operated . A copy of this schedule shall be in the hands of the Physical Plant Director prior to the start of any work . F . All work shall be performed in the presence of an Agency Representative who shall sign the job ticket documenting that the work is complete . The signatures of those performing the work shall appear on all work orders or job tickets .

Location

Country

United States of America (USA)

State

Indiana

Source

Source

Indiana Purchasing Group

URL

More Details

Record type

Tender

Article published date

2026-04-08

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender