Precast Reinforced Concrete Box Culvert ( C - 1868 )
Sector: Cement • Location: Rocky Mountain E-Purchasing System, United States of America
Source: Rocky Mountain E-Purchasing System
1 . Manufacturer shall provide structural design for the Precast Box Culvert in accordance with the following criteria : a . Traffic Loading : AASHTO HL 93 b . Dead Loading : Depth of aggregate backfill of 5 to 7 feet c . Design Standard : ASTM C - 1577 - 17 : AASHTO - LRFD d . Inside dimensions of the culvert sh
- Status
- Closed
- Sector
- Cement
- Location
- Rocky Mountain E-Purchasing System, United States of America
- Updated
- 3 Nov 2026
- Source
- Rocky Mountain E-Purchasing System
ConstructChat
Ask ConstructChat about Precast Reinforced Concrete Box Culvert ( C - 1868 )
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | 1 . Manufacturer shall provide structural design for the Precast Box Culvert in accordance with the following criteria : a . Traffic Loading : AASHTO HL 93 b . Dead Loading : Depth of aggregate backfill of 5 to 7 feet c . Design Standard : ASTM C - 1577 - 17 : AASHTO - LRFD d . Inside dimensions of the culvert shall be 15 feet wide by 5 feet high and the flow line length shall be 52 feet , pending the final engineered design . e . Exterior dimensions ( based upon wall , floor , & lid thickness ) shall be determined by the structural engineer . f . Concrete shall be Type I / II sulfate resistant Portland cement . g . Minimum clear cover on reinforcement shall be 1½ inches on all surfaces except the top deck , which shall have 2 inches minimum clear cover . Concrete clear cover on reinforcing shall not be less than ACI minimum values . h . Epoxy coated reinforcement is not desired . i . Design shall be stamped & signed by a Colorado Registered Professional Engineer . 2 . Manufacturer shall provide # 4 x 2 ’ 0 ” Dayton D - 101 - A female dowel bar splicers in two rows , at 12 ” on - center in each row for the sidewalls and top slab of the box , similar to the diagram below . The bottom slab shall have # 5 x 2 ’- 0 ” Dayton D - 101 - A dowels at 12 inches on - center . Dowel bar splicers shall be placed around the entire perimeter of each end section to develop reinforcing with the cast - in - place apron , headwall and wingwalls . |
Location
Country | United States of America (USA) |
State | Rocky Mountain E-Purchasing System |
Source
Source | Rocky Mountain E-Purchasing System |
URL |
More Details
Record type | Tender |
Sector | Cement |
Article published date | 2026-05-06 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Cement tenders in United States of America
- RFP - Thurston County Lake Management Districts Submerged Aquatic Vegetation Control
- Horsehaven Creek Culvert Replacement Project D230
- 23B49SR Marine Science Center Turtle Canopy
- Se Dixie Highway County Road A1A Utility Relocation Project
- PreQualification of Bidders for Chaboya Improvements
- 2022 Concrete Repairs Jackson Manor Subdivision
- SAC Building 10318 Exterior Paint
- Fire Station 32 ADA Restroom Improvements