logo

Process Validation for Reverse Osmosis Pilot Treatment System

Sector: Water Supply and Storage • Location: North Carolina, United States of America

Source: North Carolina Purchasing Group

Tender
Closed

The County of Cumberland requests proposals from qualified vendors to provide a pilot validation study for the treatment of landfill leachate using Specialty Reverse Osmosis ( RO ) technology . The purpose of this pilot study is to evaluate the effectiveness of the proposed system in removing PFAS compounds fr

Status
Closed
Sector
Water Supply and Storage, Power Generation (CCGT), Government, Rail, Manufacturing (Industrial), Commercial
Location
North Carolina, United States of America
Updated
3 Nov 2026
Source
North Carolina Purchasing Group

ConstructChat

Ask ConstructChat about Process Validation for Reverse Osmosis Pilot Treatment System

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Process Validation for Reverse Osmosis Pilot Treatment System” is a tender record in Taiyo, linked to the Water Supply and Storage sector. It is issued for works, goods, or services related to North Carolina, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

The County of Cumberland requests proposals from qualified vendors to provide a pilot validation study for the treatment of landfill leachate using Specialty Reverse Osmosis ( RO ) technology . The purpose of this pilot study is to evaluate the effectiveness of the proposed system in removing PFAS compounds from leachate prior to discharge to a municipal wastewater treatment facility . The study will focus on validating operational requirements , performance metrics , and treatment efficiency to inform potential full - scale implementation . The reject stream from the RO system will be evaluated by the County during this study for additional concentration and management using foam fractionation system and destruction technology . SCOPE OF WORK & VENDOR ’ S PROPOSAL CONTENT REQUIREMENTS 4 . 1 SCOPE OF WORK A . PROCESS VALIDATION FOR REVERSE OSMOSIS PILOT TREATMENT SYSTEM The Selected Vendor shall provide a fully skid - mounted Pilot Reverse Osmosis ( RO ) system and conduct a four - week onsite validation study to demonstrate system performance for PFAS removal from landfill leachate . The system shall include any and all pretreatment required for the system to operate successfully . The Vendor shall deliver and install the pilot unit and perform system commissioning to verify proper installation , instrumentation , and operational readiness , followed by system startup and establishment of stable operating conditions . The four - week validation study period shall commence only after successful completion of commissioning and startup and shall not include the time required for these activities . The Lump Sum Price shall cover the pilot system for commissioning , startup , one month of operation , and demobilization . The scope includes design , fabrication , and delivery of the pilot treatment system ; system commissioning and startup ; operator training ; technical support during installation and operation ; monitoring and data collection ; and preparation of performance reports . The Vendor shall provide delivery FOB to the Owner ’ s Fayetteville , N . C . facility . A qualified technician shall be present onsite during system setup , commissioning , and startup to verify proper installation and operation of the pilot unit . The pilot system shall be designed to treat a minimum of 5 gpm of raw leachate , produce approximately 1 gpm of RO reject , and achieve a minimum system recovery of 70 %. Any necessary pretreatment such as solids removal shall be incorporated to protect RO membranes . The system shall operate for 8 hours per day , 5 days per week , over the four - week period . The study shall include installation , commissioning , and startup of the pilot system . All electrical components shall be rated NEMA 4X , corrosion - resistant , and suitable for outdoor operation or temporary shelter . The Selected Vendor should remotely supervise pilot system operation , provide training to the Owner ’ s engineer , HDR , including HDR ’ s designated operator , and implement automated controls to safely manage the pilot system with minimal manual intervention . During the study period , effluent and RO concentrate flows shall be collected and monitored . Samples will be analyzed by the Owner ’ s engineer , HDR , through its contracted laboratory using EPA Method 1633 and other applicable standard analytical methods . Owner ’ s engineer , HDR will maintain detailed operational records , retain RO membranes for post - study evaluation , and prepare a final report summarizing system performance , sampling results , and recommendations for full - scale system design . The Counties normal work hours are Monday – Friday 6 : 00AM – 5 : 00PM . B . REQUIREMENTS The pilot system shall be capable of outdoor installation , or , if necessary , placed under a temporary tent structure . The County will provide a level gravel surface suitable for installation of the pilot treatment system within the designated installation area shown in Figures 1 and 2 . The pilot system shall draw leachate from an Owner - provided 275 - gallon feed tote , which may supply multiple treatment systems . The system shall include feed pumps , which will be provided by the Owner ’ s engineer , HDR , and all necessary pretreatment and treatment equipment . The Owner will provide a 275 - gallon effluent storage tote and a separate 275 - gallon RO concentrate storage tote . The system shall be designed to treat a minimum of 5 gpm of raw leachate and produce at least 1 gpm of RO reject , which will be further processed for concentration and residuals management , and shall meet the design criteria in Part I and Part J . All sampling and analysis shall be performed by the Owner ’ s engineer , HDR . HDR will provide an operator for 8 hours per day , while the Selected Vendor shall provide a technical representative to supervise setup and startup and to train the engineer ’ s operator . The Selected Vendor may elect to have a representative on - site for part or all of the validation study . Procedures for 8 - hour / day operation shall be developed by the Selected Vendor ; if the system needs to operate 24 hours per day , provisions must be made for automatic operation and , if necessary , effluent recirculation during unmanned periods . The Owner intends to retain RO membranes for post - study evaluation of condition and expected life . Following commissioning and startup , the system shall operate for four weeks at 8 hours per day , 5 days per week . Daily sampling will be performed by the Owner and reject flows from pretreatment will be measured and occasionally sampled for final disposition . Pretreatment is expected to include some form of solids removal . C . ELECTRICAL a . The treatment system shall be delivered as a skid - mounted systems including all electric equipment , conduit , junction boxes and wiring . b . All electrical components provided shall be rated for a corrosive environment and housed in a NEMA 4X enclosure . c . Owner will provide power to the vicinity of the treatment area . The vendor will be responsible for connection to the system . d . Installation requirements must conform to applicable codes and standards . D . OPERATION 1 . Operational Sequences : a . It is the intent of the Owner to have operators present for 8 + hours / day / 5 days per week except in extreme circumstances . If the system is proposed to run 24 hours a day , provision should be made for automatic operation and possibly to recirculate effluent as system will not be manned during off shifts . b . Leachate from the existing leachate basin , will be fed via Owner supplied pump to the a Owner supplied holding tote from which the Selected Vendor shall pump into the RO system . c . Effluent from the RO System shall be pumped into a storage tote supplied by the Owner for short term equalization and blended with treated reject stream prior to discharge to the landfill leachate collection system as indicated on Figure 2 . d . RO reject will be discharged by the Selected Vendor into a storage tote supplied by the Owner in the building for short term equalization prior to discharging into the foam fractionation system for additional concentration of PFAS compounds .

Location

Country

United States of America (USA)

State

North Carolina

Source

Source

North Carolina Purchasing Group

URL

More Details

Record type

Tender

Sector

Water Supply and Storage, Power Generation (CCGT), Government, Rail, Manufacturing (Industrial), Commercial

Article published date

2026-05-08

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender