PRT Maintenance Facility Isolation Breaker Upgrade
Bids closed Feb 2026 · West Virginia · Last reported Jan 2026
Source: West Virginia Purchasing Group
Description of isolation breakers currently installed : Manufacturer : GE Models : AK - 2 - 50 - 3 and Tri - break TB43E Deliverables from the installation work : 1 ) Removal , disposal , and replacement of all 8 isolation breakers ( Figures 1 - 4 ). 2 ) Connection of new signaling of all the new breakers into PRTs current
- Status
- Closed
- Sector
- Power Generation (CCGT), Education, Rail
- Location
- West Virginia, United States of America
- Updated
- 3 Nov 2026
- Source
- West Virginia Purchasing Group
ConstructChat
Ask ConstructChat about PRT Maintenance Facility Isolation Breaker Upgrade
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | Description of isolation breakers currently installed : Manufacturer : GE Models : AK - 2 - 50 - 3 and Tri - break TB43E Deliverables from the installation work : 1 ) Removal , disposal , and replacement of all 8 isolation breakers ( Figures 1 - 4 ). 2 ) Connection of new signaling of all the new breakers into PRTs current controls . a ) Bidder to perform verification testing on new contactors ability to reset ( close ) remotely from trips , capability to trip ( open ) with no rail power present , and report correct statuses of the different states to PRTs PLC . 3 ) Bidder shall submit manufacturers specification sheets of the proposed breakers and major components ( cabinets , signaling components , contactors , and racking devices ) 4 ) Bidder shall install new breakers according to PE stamped Drawings prepared by CJL for the new breaker installation . All enclosures layouts shall be uniform . 5 ) Bidder shall verify phasing of all power rail connections . a ) Label all phasing as A ( black ), B ( red ), and C ( blue ). 6 ) Bidder shall install each enclosure as close to the original location as possible to utilize existing conductors as defined by the drawings . 7 ) This shall be a turn - key project . Bidder shall reinstall all wires and connections associated with the above Scope of Work . Bidder shall perform a functionality check of all equipment involved during replacement and is responsible for proper functionality of units , post installation 8 ) Bidder shall coordinate work schedule with WVU . |
Location
Country | United States of America (USA) |
State | West Virginia |
Source
Source | West Virginia Purchasing Group |
URL |
More Details
Record type | Tender |
Sector | Power Generation (CCGT), Education, Rail |
Article published date | 2026-05-02 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Power Generation (CCGT) tenders in United States of America
- RFP - Thurston County Lake Management Districts Submerged Aquatic Vegetation Control
- Coatings for Wet Well and Manholes
- Security Hardware Services
- 23B49SR Marine Science Center Turtle Canopy
- Purchase and Supply of Engine Oil for the McIntosh Reciprocating Engine Project MREP
- Chambers Creek Regional Wastewater Treatment Plant BNR Aeration Basin Airflow Meters
- Se Dixie Highway County Road A1A Utility Relocation Project
- PreQualification of Bidders for Chaboya Improvements