Ready - Mix Concrete
The scope, dates and status of this tender. A free account opens every field.
Source: Missouri Purchasing Group
500 . 2 . 3 . 1 Aggregate : All Portland Cement Concrete ( PCC ) shall contain Meramec sand and gravel ( maximum size 1 ”) unless otherwise specified by the City Engineer . 500 . 2 . 3 . 2 Cement : All concrete shall be Class A with Type 1 or 1L cement . All PCC pavements shall contain 6 sacks of cement . 500 . 2 .
- Status
- Closed
- Sector
- Water Supply and Storage, Cement
- Location
- Missouri, United States of America
- Updated
- 3 Nov 2026
- Source
- Missouri Purchasing Group
ConstructChat
Ask ConstructChat about Ready - Mix Concrete
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | 500 . 2 . 3 . 1 Aggregate : All Portland Cement Concrete ( PCC ) shall contain Meramec sand and gravel ( maximum size 1 ”) unless otherwise specified by the City Engineer . 500 . 2 . 3 . 2 Cement : All concrete shall be Class A with Type 1 or 1L cement . All PCC pavements shall contain 6 sacks of cement . 500 . 2 . 3 . 2 . 1 Supplementary Cementitious Material . The use of approved percentages of fly ash , GGBFS , and silica fume shall be used in the production of Portland cement concrete . The quantity and percent use within limits shall be in accordance with the chart title “ Supplementary Cementitious Limitations ”. An adjustment in the design mix proportions will be required to correct the volume yield of the mixture . 500 . 2 . 3 . 3 Water : The maximum water per sack shall be 5 gallons . Allowable hold water must be printed on the ticket . No water shall be added to the concrete mix once it leaves the batch plant without the City ’ s approval . A driver adding water without being told to by City staff shall be grounds for rejection of the load . 500 . 2 . 3 . 4 Slump : All PCC shall have a maximum slump of 4 inches based on AASHTO T 119 . A tolerance of + ½ inch may be permitted . |
Location
Country | United States of America (USA) |
State | Missouri |
Source
Source | Missouri Purchasing Group |
URL |
More Details
Record type | Tender |
Sector | Water Supply and Storage, Cement |
Article published date | 2026-04-29 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Water Supply and Storage tenders in United States of America
- RFP - Thurston County Lake Management Districts Submerged Aquatic Vegetation Control
- Coatings for Wet Well and Manholes
- Sole Source for Wedeco UV BulbsBallets
- Security Hardware Services
- Chambers Creek Regional Wastewater Treatment Plant BNR Aeration Basin Airflow Meters
- Se Dixie Highway County Road A1A Utility Relocation Project
- UNPAINTED SNOW FENCE AND DUNE GRASS NO II
- PreQualification of Bidders for Chaboya Improvements