Rebid Three ( 3 ) Continuous Rated 67 KV Delta to 13 . 09 Y / 7 . 56KV With LTC Rated 24 / 35 . 8 / 44 . 8 MVA Power Transformers at ONAN , ONAF , ONAF
Sector: Oil and Gas • Location: North Carolina, United States of America
Source: North Carolina Purchasing Group
The Commission is requesting firm quotations for three ( 3 ) continuous rated 67KV delta to 13 . 09 Y / 7 . 56KV with LTC rated 24 / 35 . 8 / 44 . 8 MVA power transformers at ONAN , ONAF , OAF , as specified in this document , to support the operations of the Electric Support Services . PURPOSE AND BACKGROUND PWC is
- Status
- Closed
- Sector
- Oil and Gas, Power Generation (CCGT), Nuclear, Rail
- Location
- North Carolina, United States of America
- Updated
- 3 Nov 2026
- Source
- North Carolina Purchasing Group
ConstructChat
Ask ConstructChat about Rebid Three ( 3 ) Continuous Rated 67 KV Delta to 13 . 09 Y / 7 . 56KV With LTC Rated 24 / 35 . 8 / 44 . 8 MVA Power Transformers at ONAN , ONAF , ONAF
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | The Commission is requesting firm quotations for three ( 3 ) continuous rated 67KV delta to 13 . 09 Y / 7 . 56KV with LTC rated 24 / 35 . 8 / 44 . 8 MVA power transformers at ONAN , ONAF , OAF , as specified in this document , to support the operations of the Electric Support Services . PURPOSE AND BACKGROUND PWC is seeking bids for the purchase of power transformers , with orders to be placed in 2026 . The procurement includes the purchase of Three ( 5 ) 24 / 35 . 8 / 44 . 8 MVA power transformers , which must be shipped by the manufacturer on or before April 21 , 2028 . Bids should reflect firm pricing based on an order placed within sixty ( 60 ) days from the bid date . Bids must cover all associated costs , including delivery , unloading , handling , rigging , and placement of the transformers onto PWC ’ s foundation pad or piling at designated substation sites within PWC ’ s service area , which includes Fayetteville , North Carolina , and surrounding areas . PWC will specify the exact delivery site for each transformer at least thirty ( 30 ) days prior to the scheduled delivery date . PWC will ensure roadworthy access to the designated delivery sites . For evaluation purposes , bids that do not include complete oil - filling of the transformers in the base bid will have an additional $ 45 , 000 cost added to their evaluation . Manufacturers may also submit an alternate bid of a LTC mechanism for vacuum switching , stating the guaranteed minimum number of maintenance - free LTC operations . Bids guaranteeing fewer than 500 , 000 operations before maintenance will be deemed unresponsive and disqualified from consideration . TECHNICAL SPECIFICATIONS 1 . 0 Standards 1 . 1 All materials and equipment shall be new . 1 . 2 The Technical Specifications describe the type , size , and characteristics of the various materials and equipment required to be furnished . The Drawings indicate general arrangement , equipment location , and spacing . 1 . 3 Strict adherence to the Technical Specifications and Drawings is requested to facilitate checking and consideration of the Proposal . 1 . 4 The transformer manufacturer must have a USA - located repair facility to bid on this project . 1 . 5 Bid submittals shall include the following : 1 . 5 . 1 Catalog numbers , manufacturer , ratings , characteristics , types , sizes , etc ., of all major removable materials and equipment included . A simple statement that all necessary materials and equipment will be provided is not satisfactory . 1 . 5 . 2 Performance data and evidence of short circuit testing for similar designs for the several items as outlined in the Detailed Specifications . 1 . 5 . 3 The Bidder shall state in its bid how the transformers will be shipped , namely , truck or rail ; whether units shall be shipped oil - filled ; or with gas pressure , and whether bushings will be installed or removed . The bushing shall be shipped upright . 1 . 5 . 4 Prices shall include the cost of delivery to the substation site and unloading onto the pad as per Instructions to Bidders . 1 . 5 . 5 These Technical Specifications are intended for the transformer to be complete and fully operable . Any details not mentioned in the Technical Specifications but required for satisfactory operation shall be furnished and installed by the awarded Bidder including top - off oil . 1 . 5 . 6 Station power available at the PWC ’ s substation will be 120 / 240 volts , 60 Hz , single - phase . The control DC voltage at the substation sites will be 48 volts . The equipment on the transformers shall coordinate with these voltages as appropriate . 1 . 6 The transformer to be provided herein shall include a full five ( 5 ) year warranty on the complete transformer together with all parts . This warranty shall extend for five ( 5 ) years from the date of delivery . 1 . 7 All equipment and materials covered by the Technical Specifications and all tests applied to it , unless otherwise stated herein , by the applicable provisions of the latest editions of the Standards of the ASTM , ANSI , AEIC , IEEE , NEMA , NESC , and OSHA . Where the term " Standards " is used in the Technical Specifications it shall be understood to refer to the above Standards . The following is a reference list of applicable documents : IEEE C37 . 90 . 1 Surge Withstand ( SWC ) Tests IEEE C57 . 12 . 00 Standard General Requirements for Liquid Immersed Power Transformers IEEE C57 . 12 . 10 Standard Safety Requirements for Power Transformers IEEE C57 . 12 . 70 Standard Terminal Markings and Connections for Distribution and Power Transformers IEEE C57 . 12 . 80 Standard Terminology for Power and Distribution Transformers IEEE C57 . 12 . 90 Standard Test Code for Liquid Immersed Power Transformers IEEE C57 . 19 . 00 General Requirements and Test Procedure for Outdoor Power Apparatus Bushings IEEE C57 . 19 . 01 Performance Characteristics and Dimensions for Outdoor Apparatus Bushings IEEE C57 . 91 Guide for Loading Oil - Immersed Power Transformers IEEE C57 . 98 Guide for Transformer Impulse Tests IEEE C57 . 116 IEEE Guide for Transformers Directly Connected to Generators IEEE C57 . 131 Standard Requirements for Load Tap Changers IEEE C57 . 163 IEEE Guide for Establishing Power Transformer Capability while under Geomagnetic Disturbances IEEE 693 IEEE Recommended Practices for Seismic Design of Substations Doble TDRB - 291 Power Factor Test - Data Reference Book Doble - Doble Transformer Oil Purchase Specification ( TOPS ) EPRI 1015077 Guidance for Planned Replacement of Large Power Transformers at Nuclear Power Plants NEMA TR1 Audible Sound Levels for Transformers IEEE C57 . 32 Requiremen3ts , Terminology , and Test Procedure for Neutral Grounding Devices IEC 60076 - 5 Power Transformer Ability to Withstand Short Circuit |
Location
Country | United States of America (USA) |
State | North Carolina |
Source
Source | North Carolina Purchasing Group |
URL |
More Details
Record type | Tender |
Sector | Oil and Gas, Power Generation (CCGT), Nuclear, Rail |
Article published date | 2026-05-05 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Oil and Gas tenders in United States of America
- Moccasin Powerhouse Generator Step Up Transformer Installati...
- Auxiliary Water Supply System Pumping Station No. 2 Improvem...
- PARKING GARAGE JANITORIAL MAINTENANCE
- Request for Proposal RFP Elevator and Escalator Maintenance Repair
- Road Material and Hauling Services
- Used Gasoline Collection Transport Recycling Service
- Town Wide Energy Resilience Master Plan
- ANTIFREEZE OILS AND LUBRICANTS