logo

Replacement Of Backup Generator, Fuel Tank, And Automatic Transfer Switch

Combined synopsis/solicitation · Hawaii

Source: SAM.gov

Tender
Combined Synopsis/Solicitation

The USDA Medfly Preventative Release Program requires the complete removal and disposal of the existing backup generator (C100D6C Diesel Genset, 60Hz, 100kW) and Automatic Transfer Switch (ATS) (CBLC, Bypass Transfer Switch?Power Command: 150A/225A/260/300/400/600A), along with the removal and disposal of the associated diesel fuel tank, diesel fuel, and concrete equipment pad. This requirement in

Status
Closed
Sector
Raw Materials, Cement, Power Generation (CCGT), Commercial, Residential
Location
Honolulu, Hawaii, United States of America
Updated
3 Nov 2026
Source
SAM.gov

ConstructChat

Ask ConstructChat about Replacement Of Backup Generator, Fuel Tank, And Automatic Transfer Switch

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Replacement Of Backup Generator, Fuel Tank, And Automatic Transfer Switch” is a tender record in Taiyo, linked to the Raw Materials sector. It is issued for works, goods, or services related to Honolulu, Hawaii, United States of America.

Participants

Not available for this record.

Status

Original status

combined synopsis/solicitation

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

The USDA Medfly Preventative Release Program requires the complete removal and disposal of the existing backup generator (C100D6C Diesel Genset, 60Hz, 100kW) and Automatic Transfer Switch (ATS) (CBLC, Bypass Transfer Switch?Power Command: 150A/225A/260/300/400/600A), along with the removal and disposal of the associated diesel fuel tank, diesel fuel, and concrete equipment pad. This requirement includes furnishing and installing a new diesel?powered backup generator, a new Automatic Transfer Switch (ATS), a new diesel fuel tank with fuel, and a new concrete pad, as well as all items required to completely install, test, and commission the equipment in accordance with the Statement of Work. The new generator must provide a minimum standby capacity of 100 kW, equal to the existing system. Generators with capacities greater than 100 kW are acceptable and may be proposed, provided they meet all compatibility, site, electrical, and operational requirements outlined in the Statement of Work. Work includes, but is not limited to: • Decommissioning, removal, and proper disposal of the existing generator system, ATS, diesel fuel tank, diesel fuel, and concrete pad; • Furnishing and installing a new generator, ATS, diesel fuel tank, and new concrete pad; • All mechanical, electrical, piping, exhaust, grounding, controls, and associated work required for a complete and functional system; • Supplying up to 550 gallons of new diesel fuel for startup, testing, and commissioning; • Startup, testing, and commissioning of the new system; and • Providing all submittals, shop drawings, manuals, warranties, as?builts, and required training; The solicitation documents are posted below. RFIs and responses are posted below.

Original sector

Construction

Location

Country

United States of America (USA)

State

Hawaii

City

Honolulu

Source

Source

SAM.gov

URL

More Details

Record type

Tender

Sector

Raw Materials, Cement, Power Generation (CCGT), Commercial, Residential

Article published date

2026-04-18

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender