RFP for CMHS Temperature Control / Facility Management Control
One of 3,321 tenders Taiyo tracks in MITN.
Source: MITN Purchasing Group
The project consists of a comprehensive upgrade of the Temperature Control / Facility Management Control System ( FMCS ) at CMHS . Major components of the work include deployment of the latest supported version of the Niagara Framework ( N4 ) to a CPS - provided Windows Server ; migration of the existing Elementary
- Status
- Closed
- Location
- MITN, United States of America
- Updated
- 3 Nov 2026
- Source
- MITN Purchasing Group
ConstructChat
Ask ConstructChat about RFP for CMHS Temperature Control / Facility Management Control
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | The project consists of a comprehensive upgrade of the Temperature Control / Facility Management Control System ( FMCS ) at CMHS . Major components of the work include deployment of the latest supported version of the Niagara Framework ( N4 ) to a CPS - provided Windows Server ; migration of the existing Elementary School Niagara configuration to the new server ; development of a High School graphical interface mirroring the Elementary School layout ; removal and replacement of all existing unitary controllers with native BACnet controllers ; replacement of legacy controls in the gym addition currently utilizing Trane controls ; installation of a BACnet - compatible Tekmar snowmelt controller ; integration of all new and existing BACnet devices into a unified front - end system ; replacement of all space temperature sensors , CO₂ sensors , and duct pressure sensors ; addition of mixed air sensors at all air handling units ; addition of discharge air sensors at all VAV terminal units ; calibration and Test & Balance coordination for all VAV boxes ; and addition of fan status monitoring to all BAS - controlled exhaust fans . The system shall comply with ANSI / ASHRAE / ISO 135 BACnet standards and be fully web - accessible without proprietary software . |
Location
Country | United States of America (USA) |
State | MITN |
Source
Source | MITN Purchasing Group |
URL |
More Details
Record type | Tender |
Article published date | 2026-04-29 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More infrastructure tenders in United States of America
- RFP - Pro-Tem Hearing Examiner
- RFP - Thurston County Lake Management Districts Submerged Aquatic Vegetation Control
- Coatings for Wet Well and Manholes
- Veteran Transportation
- Countywide Vending Machine Services with Healthy Options
- Temporary Staffing Services Local and National
- NEW TIRES RETREADS AND TIRE SERVICES
- Youth Suicide Prevention Programming
