logo

Rubb Shelter Inspections

The scope, dates and status of this tender. A free account opens every field.

Source: SAM.gov

Tender
Special Notice

The 147th ATKW, Texas Air National Guard, intends to sole source inspection services of currently owned Aircraft Shelters. The repairs will consist of: The contractor shall provide all management, tools, supplies, equipment, and labor necessary to operate and maintain the required inspections. Structures are designed to require a minimal amount of maintenance over the life of the structures. The i

Status
Closed
Sector
Aerospace & Defense, Steel, Wind, Metal, Manufacturing (Industrial), Commercial, Residential
Location
Houston, Texas, United States of America
Updated
3 Nov 2026
Source
SAM.gov

ConstructChat

Ask ConstructChat about Rubb Shelter Inspections

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Rubb Shelter Inspections” is a tender record in Taiyo, linked to the Aerospace & Defense sector. It is issued for works, goods, or services related to Houston, Texas, United States of America.

Participants

Not available for this record.

Status

Original status

special notice

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

The 147th ATKW, Texas Air National Guard, intends to sole source inspection services of currently owned Aircraft Shelters. The repairs will consist of: The contractor shall provide all management, tools, supplies, equipment, and labor necessary to operate and maintain the required inspections. Structures are designed to require a minimal amount of maintenance over the life of the structures. The inspection should be performed bi-annually or after the structures are exposed to winds or snow loads close to the designed limit of the structure. 2.1. INSPECTION REQUIREMENTS 2.1.1. Check fabric tension around perimeter by pushing out fabric by hand from the inside of the structure at shoulder height. PVC should snap back sharply when released if correctly tensioned. Tighten as required. Removal of bird netting may be required. 2.1.2. Check tension rods along foundation for equal tension and lock nuts set. Tighten as required to equal tension in all rods in each bay area. Tighten any loose lock nuts as needed. Removal of bird netting may be required. 2.1.3. Check shackles connecting tension rods to foundation for loose pins or missing safety wire. Tighten pins as required and replace missing safety wire. Removal of bird netting may be required. 2.1.4. Check that the PVC covering is tensioned around the entire perimeter, Doors and vents. Reattach any loose PVC. Removal of bird netting may be required. 2.1.5. Check for any holes or rips in the PVC cover. Damage should be repaired according to the PVC repair procedure. Removal of bird netting may be required. 2.1.6 Check for areas of damaged galvanization or corrosion. Remove any corrosion and cover with a zinc rich coating. Removal of bird netting may be required. 2.1.7. Spot check a sample of various bolts for tightness. Tighten as required. A325 bolts are tightened according to the turn-of –the-nut method given in the A.I.S.C steel manual, 16th edition. This states that A325 bolts less than 4 diameters in length must be tightened an additional 1/3 turn past snug tight. Note A325 bolts in structure are less then 4 diameters long. All non A325 bolts are snug tight. Removal of bird netting may be required. 2.1.8. Check wind bracing cables for proper tensioning. They should be sag free. If cables are found to have sag, tighten a minimum of two full turns past the point where all the slack has been taken out of the cable. Removal of bird netting may be required. 2.1.9. Check node restraint cables for proper tension. Node restraint cables should be free of sag and snug tight. Removal of bird netting may be required. 2.1.10. STEELWORK INSPECTION - Check steelwork for missing or damagedcomponents. Replace or repair any damaged components found. Removal of bird netting may be required. The 147th ATKW, Texas Air National Guard, intends to sole source the inspections as the current assets were purchased from Rubb Inc. and must be repaired, inspected, and maintained by the company to ensure the warranty for the shelters stays intact. Work by any other vendor would void any warranty for the shelters. FAR 13.106-1(b)(1) soliciting from one responsible source.

Original sector

Not Identified

Location

Country

United States of America (USA)

State

Texas

City

Houston

Source

Source

SAM.gov

URL

More Details

Record type

Tender

Sector

Aerospace & Defense, Steel, Wind, Metal, Manufacturing (Industrial), Commercial, Residential

Article published date

2026-02-19

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender