Safety Air Monitoring Replacement Gas Chromatograph (Gc) Phase Iii

One of 9,955 tenders Taiyo tracks in Utah.

Source: SAM.gov

Tender
Combined Synopsis/Solicitation

A Gas Chromatograph (GC) instrument is needed for air monitoring in replacement of MINICAMS instruments. Procure one GC instrument with the following specifications: Detector capable of detecting halogen containing chemical agents and compounds that also do not contain a phosphorous or sulfur element. Detector is an alternate to existing Flame Photometric Detector (FPD) and Flame Ionization Detect

Status
Closed
Sector
Aerospace & Defense, Chemical (Industrial), Water Supply and Storage, Manufacturing (Industrial), Commercial, Residential
Location
Dugway, Utah, United States of America
Updated
3 Nov 2026
Source
SAM.gov

ConstructChat

Ask ConstructChat about Safety Air Monitoring Replacement Gas Chromatograph (Gc) Phase Iii

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Safety Air Monitoring Replacement Gas Chromatograph (Gc) Phase Iii” is a tender record in Taiyo, linked to the Aerospace & Defense sector. It is issued for works, goods, or services related to Dugway, Utah, United States of America.

Participants

Not available for this record.

Status

Original status

combined synopsis/solicitation

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

A Gas Chromatograph (GC) instrument is needed for air monitoring in replacement of MINICAMS instruments. Procure one GC instrument with the following specifications: Detector capable of detecting halogen containing chemical agents and compounds that also do not contain a phosphorous or sulfur element. Detector is an alternate to existing Flame Photometric Detector (FPD) and Flame Ionization Detector (FID) Chromatographic column: MXT-1701 phase Air sampling Quick Change Trap Module with flow rate through the trap of at least 500mL/min External mass flow controller, ability to capture the flow meter readings Oven programmable from ambient to 400? Cycle time from injection to injection of 15 minutes or less Visible and audible alarms for system faults and sample concentration detections Integrated GC engine, NUMAVIEW with touchscreen display, integrated processor, and storage. Data logging. Ability to capture instrument set points and measured values such as: sample flow, temperatures, pressures, calibration, concentration, injection type – calibration, service, sample, etc. Data captured locally with the ability to retrieve and use for other reporting or calculating of sample data. Automatic calibration feature. Calibration of the instrument using an averaged single point or multi-point calibration curve. Capable of calibrating and obtaining sample concentrations using the onboard integration engine, and values displayed on the graphical user interface. Heated exhaust to prevent expulsion of water. Detector exhaust must expel water in gas/vapor form elimination water drip from the instrument detector. Sample bypass capability. Ability for continuous sample flow at inlet in a bypass state. A minimum flow of 500mL/min required for bypass capability. GC approximate dimensions - 17” x 11” x 8.5” (width x height x depth) Instrument weight approximately 25 pounds Shipping: Delivery shall be completed by 30 September 2026 or upon customer notification.

Original sector

Not Identified

Location

Country

United States of America (USA)

State

Utah

City

Dugway

Source

Source

SAM.gov

URL

More Details

Record type

Tender

Sector

Aerospace & Defense, Chemical (Industrial), Water Supply and Storage, Manufacturing (Industrial), Commercial, Residential

Article published date

2026-03-25

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender