logo

Samples for Urinalysis and Related Procedures ( 2026 - UWMSN - 01304 - RFB )

The scope, dates and status of this tender. A free account opens every field.

Source: Wisconsin Purchasing Group

Tender
Closed

The University of Wisconsin - Madison , hereinafter referred to as the “ University ”, through its Purchasing Services Department , hereinafter referred to as “ Purchasing ”, on behalf of the Wisconsin State Laboratory of Hygiene Proficiency Testing Department , hereinafter referred to as “ Department ” or “ WSLH - PT ”, requests

Status
Closed
Sector
Education, Manufacturing (Industrial), Seaport, Residential
Location
Wisconsin, United States of America
Updated
3 Nov 2026
Source
Wisconsin Purchasing Group

ConstructChat

Ask ConstructChat about Samples for Urinalysis and Related Procedures ( 2026 - UWMSN - 01304 - RFB )

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Samples for Urinalysis and Related Procedures ( 2026 - UWMSN - 01304 - RFB )” is a tender record in Taiyo, linked to the Education sector. It is issued for works, goods, or services related to Wisconsin, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

The University of Wisconsin - Madison , hereinafter referred to as the “ University ”, through its Purchasing Services Department , hereinafter referred to as “ Purchasing ”, on behalf of the Wisconsin State Laboratory of Hygiene Proficiency Testing Department , hereinafter referred to as “ Department ” or “ WSLH - PT ”, requests bids for the purchase of Samples for Urinalysis and Related Procedures . GENERAL SPECIFICATIONS MEET SPECIFICATIONS A . Sample Specifications YES NO A . 1 Samples must be human based , unless otherwise specified . A . 2 Vendors must manufacture product ( s ) in conformance with the current Good Manufacturing Practices ( cGMP ) as defined by the Food and Drug Administration ( FDA ). A . 3 Vendor must be International Standardization Organization ( ISO ) certified and provide documentation of certification . A . 4 Vendor must provide a Certificate of Analysis ( COA ) for every sample with each shipment . For purposes of this specification , production or internal quality control data are also acceptable . This will be for WSLH PT internal use only and is not considered to be a claimed performance characteristic of the product . A . 5 COAs must include expiration dates and sample storage requirements . A . 6 COAs must be provided to WSLH PT by mail or electronically at least one week prior to WSLH PT scheduled ship date . A . 7 Sample performance documented on each COA must be from the final product shipped to WSLH PT . A . 8 Analyzer ( s ) mfg / model ( s ) used in testing for COA documentation must be recorded on COA . A . 9 Samples must test non - reactive for Human Immunodeficiency Virus ( HIV ), Hepatitis B and Hepatitis C . Documentation of testing by techniques approved by the FDA must be provided on the COA . A . 10 Samples must be free of microbial contaminants that could damage the product . A . 11 Microbial incidence must be reported on the COA . A . 12 Vendor must be capable of providing samples specified in this contract on a regular basis beginning no later than March 2027 . A . 13 Upon request , vendors must supply a representative test sample and / or COA prior to acceptance of the bid . A . 14 Vendor , at no cost to WSLH PT , must replace any samples found not suitable for analysis . A . 15 The vendor must provide safety data sheets ( SDS ) for all applicable samples . A . 16 Vendor must disclose all methods with which the samples offered are known to be incompatible . A . 17 Samples must be of different levels ( normal and abnormal ) which span the analytical range for most instrument / kits , representative of clinical human samples . A . 18 Upon request , vendor must provide WSLH PT the product name ( s ), number of levels available , projected annual production schedule ( s ), product insert ( s ) and assay sheet ( s ). A . 19 For each non - custom product , the vendor must submit a product insert and potential analyte concentrations from which to choose . A . 20 Samples supplied must be free from known interferences and suitable for use on the most common instruments / kits currently on the market . Written documentation of compatibility tests must be available to WSLH PT upon request . A . 21 Vendor must notify WSLH PT of any changes to additives and / or preservatives made to the product after the original bid acceptance . A . 22 Samples must be free from fibrin and other particulate matter which might interfere with sample processing or analysis . These specifications are in addition to the General Bid Specifications . MEET SPECIFICATIONS ITEM SAMPLE SPECIFIC SPECIFICATIONS YES NO 1 . Samples must be at least 10 mL liquid human urine matrix with human source material . 2 . Samples must be suitable to test for qualitative and semi - quantitative biochemical components of human urine . 3 . Vendor must provide six sample formulations to accommodate a three - sample program that ships two times a year . 4 . WSLH PT will have the ability to select from the levels of material offered and will determine the labeling order for each sample . 5 . Samples must contain the following analytes : bilirubin , glucose , blood / hemoglobin , ketones , leukocyte esterase , nitrite , pH , protein , specific gravity , urobilinogen , and qualitative urine hCG . 6 . Samples may contain the following additional analytes : Microalbumin , Creatinine If present , please list on the COA . 7 . Samples must be compatible with visually read urine reagent strips as well as automated and semi - automated urinalysis instruments . Strips and instruments include , but are not limited to , Siemens reagent strips and CLINITEK analyzers ; Roche reagent strips and analyzers ( cobas u and Urisys ); Aution Max AX - 4030 ; McKesson Consult reagent strips and analyzers ; and other urine reagent strips on the market . Vendor must disclose any analyte / instrument compatibility issues below . ___________________________________________________________ 8 . Samples may be suitable for use with urine confirmatory tests for bilirubin , ketones and reducing substances ( example : AimTab ). 9 . Samples may be suitable for use with Sulfosalicylic Acid test for total protein . 10 . Samples must be compatible with qualitative urine hCG kits . 11 . Samples must be free from interfering substances that may cause invalid urine hCG results . 12 . The sample vial must have enough depth to allow common urinalysis reagent dipsticks to be totally submerged in the sample . 13 . Samples must have a minimum closed vial refrigerator or room temperature stability that extends the duration of the WSLH PT event testing period . The WSLH PT event testing periods end 4 - 5 weeks after the WSLH PT event ship date . 14 . Vendor must disclose approximate open vial stability below : Refrigerator open vial stability ( if applicable ): _____________________ Room temperature open vial stability ( if applicable ): _________________ 15 . Sample stability and integrity must be maintainable during the WSLH PT 2 - day shipping to participants ( samples must not be labile under normal shipping conditions ).

Location

Country

United States of America (USA)

State

Wisconsin

Source

Source

Wisconsin Purchasing Group

URL

More Details

Record type

Tender

Sector

Education, Manufacturing (Industrial), Seaport, Residential

Article published date

2026-05-06

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender