logo

Sellafield Skip Size Reduction Facility Enclosure

Sector: Commercial • Location: United Kingdom

Source: Open Contracting Data Standard (OCDS)

Tender
Complete

The enclosure will be utilised for removing Intermediate Level Waste (ILW) Pond Skips from PAC-TEK Bags and adding loose contamination Fixodent. The current Poly Vinyl Chloride (PVC) enclosure has an entry doorway from the Bulky Items Area and an exit doorway to the building door between the Bulky Items Area and Waste Sort Area, both features that need to be provided on the new enclosure. There i

Status
Closed
Sector
Commercial
Location
United Kingdom
Updated
3 Nov 2026
Source
Open Contracting Data Standard (OCDS)

ConstructChat

Ask ConstructChat about Sellafield Skip Size Reduction Facility Enclosure

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Sellafield Skip Size Reduction Facility Enclosure” is a tender record in Taiyo, linked to the Commercial sector. It is issued for works, goods, or services related to United Kingdom.

Participants

Not available for this record.

Status

Original status

complete

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

The enclosure will be utilised for removing Intermediate Level Waste (ILW) Pond Skips from PAC-TEK Bags and adding loose contamination Fixodent. The current Poly Vinyl Chloride (PVC) enclosure has an entry doorway from the Bulky Items Area and an exit doorway to the building door between the Bulky Items Area and Waste Sort Area, both features that need to be provided on the new enclosure. There is a roof opening/hatch to allow 3t Maintenance Crane access and a clear panel window for crane operator viewing which also need to be provided. On the current PVC enclosure, there is ventilation extract with HEPA Filtration but due to the current design of the enclosure, this system fails the Ventilation Technical Specialist Group (VTSG) testing. The new enclosure is required to pass the VTSG testing. VTSG’s test criteria for a C3 containment is an air tightness test with a minimum velocity of 0.5m/s measured at all points across the open

Location

Country

United Kingdom (UK)

Source

Source

Open Contracting Data Standard (OCDS)

URL

More Details

Record type

Tender

Sector

Commercial

Article published date

2026-03-16

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender