The physiological function test system 1 set
Sector: Education • Location: Japan
Source: Japan External Trade Organization (JETRO)
Classification of the products to be procured : 22, 3 Nature and quantity of the products to be purchased : The physiological function test system set Type of the procurement : Purchase Basi requirements of the procurement : A The physiological function test system is capable of collecting, managing, and viewing physiological test data, and must have the ability to view it from electroni medical
- Status
- Prospective
- Sector
- Education, Hospital
- Location
- Japan
- Updated
- 3 Nov 2026
- Source
- Japan External Trade Organization (JETRO)
ConstructChat
Ask ConstructChat about The physiological function test system 1 set
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | prospective |
Taiyo status | Prospective |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | Classification of the products to be procured : 22, 3 Nature and quantity of the products to be purchased : The physiological function test system set Type of the procurement : Purchase Basi requirements of the procurement : A The physiological function test system is capable of collecting, managing, and viewing physiological test data, and must have the ability to view it from electroni medical record terminals via the hospital network. B Test data managed by the physiological function test system must be centrally managed in a single database. C The physiological function test system must have the ability to set access permissions (view, edit, manage, etc.) for each user ID, allowing for individual permission control. D The physiological function test system must have the ability to link test order information with existing Nihon Kohden electrocardiographs, exercise stress testing devices, long-term electrocardiogram analyzers, electroencephalographs, and electromyography/evoked potential testing devices that are connected to the physiological function test system. E The physiological function test system must have the ability to create test results in report format and output them in a standard format such as PDF. F The physiological function test system must have the ability to display and compare test data with past test data, supporting time-series evaluation of the same patient. G The EEG device must be capable of connecting to the physiological function test system via the hospital network and have the functionality to share test order information and transmit test results. H The EEG device must be capable of multi-channel EEG measurement and have sufficient resolution and sampling performance for clinical testing. I The EEG device must have the functionality to analyze EEG frequencies. J The EEG device must be capable of connecting to a video camera and have the functionality to display and save images during EEG testing. K The EMG/evoked potential testing device must be capable of connecting to the physiological function test system via the hospital network and have the functionality to share test order information and transmit test results. L The EMG/evoked potential testing device must be equipped with an amplifier that is resistant to discrimination ratios and noise, and be compatible with various evoked potential tests such as nerve conduction tests, auditory evoked response tests, and somatosensory evoked potential tests. M The EMG/evoked potential testing device must have the functionality to deliver electrical, acoustic, and visual stimulation. Time limit for the submission of the requested material : 1 : 0 August, 202 Contact point for the notice : Tadahiro Ueda, Contract Section, Accounting and Procurement Division, Kyoto University Hospital, 5 Kawahara-cho Shogoin Sakyo-ku Kyoto-shi 606-850 Japan, TEL 075-751-3025 |
Location
Country | Japan |
Source
Source | Japan External Trade Organization (JETRO) |
URL |
More Details
Record type | Tender |
Sector | Education, Hospital |
Article published date | 2026-06-22 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Education tenders in Japan
- Protestant Coordinator Of Religious Education (Cre)
- Misawa Air Base F-35 Engine Run Simulator
- Dowea - Safety Aides And Attendant Services, Mainland, Japan
- Okinawa Total Maintenance Contract - Amendment 0003
- Dowea Pacific South District Warehouse Support Services
- Okinawa Total Maintenance Contract - Amendment 0003
- Sources Sought Notice And Request For Information (Rfi) For Pacific East Maintenance Services
- Dowea Pacific South District Warehouse Support Services
