Three ( 3 ) 8 ' x 8 ' Communication Shelters for MnDOT

The scope, dates and status of this tender. A free account opens every field.

Source: Minnesota Purchasing Group

Tender
Closed

The purpose of this Contract is to provide three ( 3 ) 8 ’ X 8 ’ communication shelters used to cover and protect MnDOT ’ s Intelligent Transportation Management System ( TMS ). Specifications include , but are not limited to : 7 . 1 The TMS Shelter Cabinet must conform to the latest edition of the International

Status
Closed
Sector
Metal, Forest Products and Packaging, Steel, Telecommunications, Commercial, Cement, Broadband
Location
Minnesota, United States of America
Updated
3 Nov 2026
Source
Minnesota Purchasing Group

ConstructChat

Ask ConstructChat about Three ( 3 ) 8 ' x 8 ' Communication Shelters for MnDOT

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Three ( 3 ) 8 ' x 8 ' Communication Shelters for MnDOT” is a tender record in Taiyo, linked to the Metal sector. It is issued for works, goods, or services related to Minnesota, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

The purpose of this Contract is to provide three ( 3 ) 8 ’ X 8 ’ communication shelters used to cover and protect MnDOT ’ s Intelligent Transportation Management System ( TMS ). Specifications include , but are not limited to : 7 . 1 The TMS Shelter Cabinet must conform to the latest edition of the International Building Code and Chapter 1323 of the Minnesota Energy Code . 7 . 2 The manufactured shelter must provide a temperature - controlled environment for electrical , electronic , fiber optic devices , and comply with the following additional specifications : 7 . 2 . 1 The shelter size must be nominally : 8 ’ W ( OD ) X 8 ’ L ( OD ) X 8 ’ H ( ID ) and be designed to mount to a concrete slab foundation . The plans and details for this foundation must be provided by the shelter manufacturer . 7 . 2 . 2 5052 - H32 aluminum ASTM B209 ( marine grade ) must be utilized for the exterior construction . 7 . 2 . 3 The interior walls must be covered with minimum ½ inch thick fire - retardant plywood and faced with white coating or sheeting . 7 . 2 . 4 No wood products must be used for construction of the shelter except for the interior face of the walls . 7 . 2 . 5 The electrical distribution panel must be rated for 120 / 240 VAC , 60 A . 7 . 2 . 5 . 1 The main breaker must be a 60 amp 2 pole . 7 . 2 . 5 . 2 Each branch circuit must be rated at 20 A . 7 . 2 . 5 . 3 All circuit breakers must be labeled appropriately . 7 . 2 . 5 . 4 In addition to the required breakers , four spare breakers rated at 20 A must be installed and labeled as SPARE . 7 . 2 . 5 . 5 The panel must have a 1½ ” metal conduit running to the side wall with a 1½ ” rigid type - LB threaded conduit body connected on the exterior wall for future service conductors . 7 . 2 . 6 One master ground bar made of copper must be installed to the left or right of the conduit / cable entrance tower 2 feet above the floor and mounted off the wall using electrical isolators . The dimensions must be 0 . 25 ” thick , 4 .” wide and 12 ” long .

Location

Country

United States of America (USA)

State

Minnesota

Source

Source

Minnesota Purchasing Group

URL

More Details

Record type

Tender

Sector

Metal, Forest Products and Packaging, Steel, Telecommunications, Commercial, Cement, Broadband

Article published date

2026-05-02

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender