Three-Phase Oil Transformer In Hermetic Design
The scope, dates and status of this tender. A free account opens every field.
Source: SAM.gov
1 each three-phase oil transformer in hermetic design according to DIN EN 50588 Loss series AAo/AK with reduced power losses in accordance with the European Commission's Ecodesign Regulation, with zere tolerance, stage 2 from July 1, 2021, with the following specs: High voltage (HV) 20,000 V; Low voltage (LV) 400/230 V; Voltage Tapping 5 steps ± 2x2.5%; Vector Group Dyn5; Frequency 50 Hz; Cooling
- Status
- Closed
- Sector
- Residential, Oil and Gas, Power Transmission, Aerospace & Defense, Power Generation (CCGT), Manufacturing (Industrial), Commercial, Government
- Location
- Spangdahlem, DE-RP, Germany
- Updated
- 3 Nov 2026
- Source
- SAM.gov
ConstructChat
Ask ConstructChat about Three-Phase Oil Transformer In Hermetic Design
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | presolicitation |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | 1 each three-phase oil transformer in hermetic design according to DIN EN 50588 Loss series AAo/AK with reduced power losses in accordance with the European Commission's Ecodesign Regulation, with zere tolerance, stage 2 from July 1, 2021, with the following specs: High voltage (HV) 20,000 V; Low voltage (LV) 400/230 V; Voltage Tapping 5 steps ± 2x2.5%; Vector Group Dyn5; Frequency 50 Hz; Cooling Method 3. Length approx. 1,340 mm; Width approx. 1,045 mm; Height approx. 1,630 mm; Weight approx. 2,650 kg; Oil weight approx. 490 kg. Additional accessories: 1 each Transformer protection relay RIS/DMCR/DGPT2 3 each Euromold plug bushings for 250A angle plugs 4 each Transformer connection terminals, four wire, 35-240 mm², for M30x2 feed-through, for terminals 2DIRECT-CL/35-240/4x/L/M30x2 (Pfisterer 331 747 001); clamps for terminal bolts compliant with DIN EN 50386; DIN EN 50386 compliant bolted connections (1 kV). Type tested in compliance with IEC 61238 with Cu cables, 240 mm². 4 each Cover for 2DIREKT Four Wire Terminal, for Bolted Connections M30-M24, Indoor Use (Pfisterer 331 347 001). 4 each additional covers for Screw with Ball Pin. 4 each vibration dampers EK90 60 meters 20 kV cable type N2XSY 1 x 35/RM 16. The intention is to award to the vendor who is deemed responsible, responsive, and represents the best value to the Government based on selection of the lowest total price that is deemed technically acceptable. In accordance with FAR 12.201-1 (c) (2) Contracting Officer has chosen to solicit quotations directly from suppliers. When soliciting directly- (i) Post a presolicitation notice in the GPE according to subpart 5.1, unless an exception in 5.101(b) applies. (ii) Solicit quotations from at least three sources; and (iii) Whenever practicable, solicit quotations from two sources not included in the previous solicitation. In case you are interested in receiving the solicitation please feel free to contact the Primary or the Secondary Point of Contact. |
Original sector | Not Identified |
Location
Country | Germany |
State | DE-RP |
City | Spangdahlem |
Source
Source | SAM.gov |
URL |
More Details
Record type | Tender |
Sector | Residential, Oil and Gas, Power Transmission, Aerospace & Defense, Power Generation (CCGT), Manufacturing (Industrial), Commercial, Government |
Article published date | 2026-02-07 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Residential tenders in Germany
- Replace 16 Each Foldable Bay Doors, Building 308, Usag Bavaria, Grafenwoehr Military Community – Rose Barracks (Project Lk-08630-1J)
- Fy27 Secure Facilities Design-Build (Db) And Design-Bid-Build (Dbb) Construction Multiple Award Task Order (Matoc)
- Maintenance & Repair Of Emergency Power And Power Generation Systems Consisting Of Emergency Power System (Eps), Uninterruptible Power Supply (Ups) And Photovoltaic (Pv) Throughout Usag Wiesbaden
- Maintenance & Repair Of Emergency Power And Power Generation Systems Consisting Of Emergency Power System (Eps), Uninterruptible Power Supply (Ups) And Photovoltaic (Pv) Throughout Usag Wiesbaden
- Rfi For 220V / 50Hz Power Tools For Oconus Operations (Europe)
- Sewer Line Renovation, Frankfurt
- Removal/ Remediation Of Asbestos Containing Doors In Various Bldgs, Usag Bavaria, Grafenwoehr Military Community - Tower Barracks
- Exterior Upgrade, Frankfurt