Three section combination - ( 2 ) Inside Walk - In Freezers and ( 1 ) Walk - In Cooler - Lamar County High School
The scope, dates and status of this tender. A free account opens every field.
Source: Alabama Purchasing Group
THREE SECTION COMBINATION INDOOR WALK - IN COOLER / FREEZER SPECIFICATION Lamar County Schools Lamer County High School This bid is a turn - key operation to include removal of the existing three section indoor walk - in cooler and freezers , along with shelving , tile flooring , and refrigeration . Installation of new
- Status
- Closed
- Sector
- Metal, Geothermal, Manufacturing (Industrial)
- Location
- Alabama, United States of America
- Updated
- 3 Nov 2026
- Source
- Alabama Purchasing Group
ConstructChat
Ask ConstructChat about Three section combination - ( 2 ) Inside Walk - In Freezers and ( 1 ) Walk - In Cooler - Lamar County High School
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | THREE SECTION COMBINATION INDOOR WALK - IN COOLER / FREEZER SPECIFICATION Lamar County Schools Lamer County High School This bid is a turn - key operation to include removal of the existing three section indoor walk - in cooler and freezers , along with shelving , tile flooring , and refrigeration . Installation of new three section indoor walk - in cooler and freezer boxes , refrigeration equipment , plumbing , complete finishing , new tile flooring at connecting area inside kitchen , and re - installation of existing shelving and dunnage racks . GENERAL SPECIFICATIONS : The THERMO - KOOL or " Pre - Approved " equal three section walk - in specified shall be prefabricated modular construction . It shall be designed and constructed to allow fast and easy field assembly , disassembly , relocation and enlargement by the addition of like modular panels . Walk - in shall be designed and constructed as shown on plan . Overall exterior size of the combination walk - in cooler and freezers shall be approximately 19 ft 3 in 24 ft 5 in x 8 ft 6 in height , to fit exact job site requirements . The interior dimensions of the cooler section shall be approximately 18 ft 7 in x 8 ft O in . The interior dimensions of freezer section # 1 shall be approximately 18 ft 7 in x 8 ft 2 in . The interior dimensions of freezer section # 2 shall be approximately 11 ft 10 in x 6 ft 11 in . All measurements must be field verified prior to construction by dealer . PANEL CONSTRUCTION : Wall and ceiling panel widths shall be within 1 " increments up to 46 " wide . Corner panels shall be 90 - degree angle , 12 " x 12 ". All panels shall be interchangeable with like panels for fast and easy assembly . Exterior finish to be Stucco Galvanized . Interior finish to be Stucco Galvanized Walls and prepainted White Stucco Galvanized on the ceiling panels . All panels shall consist of metal pans formed to precise dimensions . Insulation shall be " foamed - in - place " urethane to bond permanently to complete inner surfaces of both interior and exterior metal pans to form strong rigid unit . Panels shall not have internal wood or metal support , framing , straps , or other non - insulating members . Each panel shall be 100 % urethane foam insulation exclusive of metal pans . Perimeter structure shall be formed of DURATHANE , high density urethane insulation forming tongues and grooves to assure vapor and airtight joints and to prevent pre - installation damage and deterioration of exposed urethane surfaces . PANEL WARRANTY : Panels shall be covered by a Ten - Year Factory Warranty . INSULATION : Lamar County High School Insulation shall be 4 " thick rigid , zero ozone depleting HFC 134a blown Class I urethane foam classified according to UL 723 ( ASTM - E - 84 ) as tested by Underwriters Laboratories , Inc . The core material has a flame spread of 25 or less and a smoke density of 250 . The urethane foam is foamed - in - place to bond to inner surfaces of metal pans having an average thermal conductivity ( K factor ) of 0 . 13 BTU / hr ./ sq . fft . per degrees / Fahrenheit / inch . As tested in accordance with ASTM C 518 - 2004 , the R factor for coolers at temperatures of 55 degrees F is greater than 29 . 0 for 4 " thick panels , freezers at temperatures of 20 degrees F the R factor is greater than 32 . 0 for 4 " thick panels . The prefabricated urethane foamed panels shall be supplied with a Class I fire hazard classification according to UL 723 ( ASTM - E - 84 ) as tested by Underwriters Laboratories , Inc . Panels shall have a flame spread rating of 25 or less and bear a certifying Underwriters Laboratories , Inc . label . This rating is not intended to reflect hazards presented by this or any other material under actual fire conditions |
Location
Country | United States of America (USA) |
State | Alabama |
Source
Source | Alabama Purchasing Group |
URL |
More Details
Record type | Tender |
Sector | Metal, Geothermal, Manufacturing (Industrial) |
Article published date | 2026-03-27 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Metal tenders in United States of America
- Token Creek Roof Replacements
- HVAC Ice Machine Servicing and Sheet Metal Fabrication
- Jail Courthouse Walkway Project
- RFP 887702021MF Rapid Response Fire Boat for Norfolk FireRescue
- Various Locations Sewer Replacement No. 9 [BID TABULATION]
- Millbrae Warehouse Loading Dock Repair
- Biosolids Digester Facilities - Southeast Treatment Plant T-...
- Electrical (C-10 License), San Francisco, San Mateo, Santa C...