THREE SECTION COMBINATION INDOOR WALK - IN COOLER / FREEZER SPECIFICATION Lamar County Schools Lamer County High School This bid is a turn - key operation to include removal of the existing three section indoor walk - in cooler and freezers , along with shelving , tile flooring , and refrigeration . Installation of new

Status
Closed
Sector
Metal, Geothermal, Manufacturing (Industrial)
Location
Alabama, United States of America
Updated
3 Nov 2026
Source
Alabama Purchasing Group

ConstructChat

Ask ConstructChat about Three section combination - ( 2 ) Inside Walk - In Freezers and ( 1 ) Walk - In Cooler - Lamar County High School

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Three section combination - ( 2 ) Inside Walk - In Freezers and ( 1 ) Walk - In Cooler - Lamar County High School” is a tender record in Taiyo, linked to the Metal sector. It is issued for works, goods, or services related to Alabama, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

THREE SECTION COMBINATION INDOOR WALK - IN COOLER / FREEZER SPECIFICATION Lamar County Schools Lamer County High School This bid is a turn - key operation to include removal of the existing three section indoor walk - in cooler and freezers , along with shelving , tile flooring , and refrigeration . Installation of new three section indoor walk - in cooler and freezer boxes , refrigeration equipment , plumbing , complete finishing , new tile flooring at connecting area inside kitchen , and re - installation of existing shelving and dunnage racks . GENERAL SPECIFICATIONS : The THERMO - KOOL or " Pre - Approved " equal three section walk - in specified shall be prefabricated modular construction . It shall be designed and constructed to allow fast and easy field assembly , disassembly , relocation and enlargement by the addition of like modular panels . Walk - in shall be designed and constructed as shown on plan . Overall exterior size of the combination walk - in cooler and freezers shall be approximately 19 ft 3 in 24 ft 5 in x 8 ft 6 in height , to fit exact job site requirements . The interior dimensions of the cooler section shall be approximately 18 ft 7 in x 8 ft O in . The interior dimensions of freezer section # 1 shall be approximately 18 ft 7 in x 8 ft 2 in . The interior dimensions of freezer section # 2 shall be approximately 11 ft 10 in x 6 ft 11 in . All measurements must be field verified prior to construction by dealer . PANEL CONSTRUCTION : Wall and ceiling panel widths shall be within 1 " increments up to 46 " wide . Corner panels shall be 90 - degree angle , 12 " x 12 ". All panels shall be interchangeable with like panels for fast and easy assembly . Exterior finish to be Stucco Galvanized . Interior finish to be Stucco Galvanized Walls and prepainted White Stucco Galvanized on the ceiling panels . All panels shall consist of metal pans formed to precise dimensions . Insulation shall be " foamed - in - place " urethane to bond permanently to complete inner surfaces of both interior and exterior metal pans to form strong rigid unit . Panels shall not have internal wood or metal support , framing , straps , or other non - insulating members . Each panel shall be 100 % urethane foam insulation exclusive of metal pans . Perimeter structure shall be formed of DURATHANE , high density urethane insulation forming tongues and grooves to assure vapor and airtight joints and to prevent pre - installation damage and deterioration of exposed urethane surfaces . PANEL WARRANTY : Panels shall be covered by a Ten - Year Factory Warranty . INSULATION : Lamar County High School Insulation shall be 4 " thick rigid , zero ozone depleting HFC 134a blown Class I urethane foam classified according to UL 723 ( ASTM - E - 84 ) as tested by Underwriters Laboratories , Inc . The core material has a flame spread of 25 or less and a smoke density of 250 . The urethane foam is foamed - in - place to bond to inner surfaces of metal pans having an average thermal conductivity ( K factor ) of 0 . 13 BTU / hr ./ sq . fft . per degrees / Fahrenheit / inch . As tested in accordance with ASTM C 518 - 2004 , the R factor for coolers at temperatures of 55 degrees F is greater than 29 . 0 for 4 " thick panels , freezers at temperatures of 20 degrees F the R factor is greater than 32 . 0 for 4 " thick panels . The prefabricated urethane foamed panels shall be supplied with a Class I fire hazard classification according to UL 723 ( ASTM - E - 84 ) as tested by Underwriters Laboratories , Inc . Panels shall have a flame spread rating of 25 or less and bear a certifying Underwriters Laboratories , Inc . label . This rating is not intended to reflect hazards presented by this or any other material under actual fire conditions

Location

Country

United States of America (USA)

State

Alabama

Source

Source

Alabama Purchasing Group

URL

More Details

Record type

Tender

Sector

Metal, Geothermal, Manufacturing (Industrial)

Article published date

2026-03-27

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender