2 . 1 General The BBS shall provide the following operational modes when operating on battery power : • Full operation of all traffic signal devices • Flash operation • Combination of full and flash operation 2 . 2 Run Time The BBS shall provide a minimum of 8 . 0 hours of full - time operation with a 450

Status
Closed
Sector
Energy Storage, Power Generation (CCGT)
Location
Missouri, United States of America
Updated
3 Nov 2026
Source
Missouri Purchasing Group

ConstructChat

Ask ConstructChat about Traffic Signal Battery Backup Systems

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Traffic Signal Battery Backup Systems” is a tender record in Taiyo, linked to the Energy Storage sector. It is issued for works, goods, or services related to Missouri, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

2 . 1 General The BBS shall provide the following operational modes when operating on battery power : • Full operation of all traffic signal devices • Flash operation • Combination of full and flash operation 2 . 2 Run Time The BBS shall provide a minimum of 8 . 0 hours of full - time operation with a 450 - watt load . The minimum battery size requirement is listed in section 7 . 0 , Battery Type . 2 . 3 Compatibility The BBS shall be compatible with Model 332 , 336 , and 337 cabinets ; the ITS cabinet ; model 170 and 2070 controllers and any NEMA style cabinet and enclosures ; the advanced transportation controller ; and all cabinet components for full time operation . 2 . 4 Output Capacity The BBS shall provide a minimum of 1100W / 1100VA @ 25 ° C active output capacity with 83 percent minimum inverter efficiency with 30 % minimum loading . 2 . 5 Output Voltage When operating in backup mode , the BBS output shall be 120VAC ± 2 %, pure sine wave output , ≤ 3 % THD , 60Hz ± 0 . 3 Hz . 2 . 6 DC System Voltage The BBS DC system voltage shall be 48VDC nominal .

Location

Country

United States of America (USA)

State

Missouri

Source

Source

Missouri Purchasing Group

URL

More Details

Record type

Tender

Sector

Energy Storage, Power Generation (CCGT)

Article published date

2026-04-29

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender