logo

TRAILER MOUNTED SEWER CLEANER

Closed · Georgia · Last reported Jan 2026

Source: Georgia Purchasing Group

Tender
Closed

A . WATER TANK SYSTEM : 1 . Water tank capacity shall be a total of 700 gallons with each tank having a capacity of 350 gallons . 700 - gallon tanks consisting of a single chamber are are not acceptable due to excessive water surging while driving . This will prove a minimum run time of at least 17

Status
Closed
Sector
Water Supply and Storage, Chemical (Industrial), Oil and Gas, Waste Processing and Treatment, Metal, Steel, Manufacturing (Industrial)
Location
Georgia, United States of America
Updated
3 Nov 2026
Source
Georgia Purchasing Group

ConstructChat

Ask ConstructChat about TRAILER MOUNTED SEWER CLEANER

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “TRAILER MOUNTED SEWER CLEANER” is a tender record in Taiyo, linked to the Water Supply and Storage sector. It is issued for works, goods, or services related to Georgia, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

A . WATER TANK SYSTEM : 1 . Water tank capacity shall be a total of 700 gallons with each tank having a capacity of 350 gallons . 700 - gallon tanks consisting of a single chamber are are not acceptable due to excessive water surging while driving . This will prove a minimum run time of at least 17 minutes . Tanks shall be constructed of . 375 ” thick High - Density Polyethylene with a five ( 5 ) year warranty . Y N 2 . The tank shall be equipped with an access hole at the top to allow for cleaning Y N 3 . Shall be constructed of Polyethylene to be ultraviolet stabilized to prevent material breakdown . y N 4 . Tanks constructed of steel will not be acceptable due to the potential of water pump damage by rust and corrosion particles . Y N 5 . Tank draining shall be provided via a 2 ” drain minimum . Y N 6 . All plumbing from water tank to pump inlet shall contain the tank valve , inline filter , and water dump valve . Y N 7 . A water level sight gauge shall be provided on the side of the tank near the operator ’ s station . Y N 8 . Tanks must be secured with resilient nylon straps that wrap around tank . Bolt on tanks or tanks secured with metal straps will not be accepted . Y N B . FILL STATION : 1 . There shall be an open port at the top of the water tank to allow access to the tank for filling with water . A filter shall be provided to prevent debris entering the water tank and is removable for cleaning . Y N 2 . An overhead type tank filling assembly with a 2 - 1 / 2 ” fire hydrant fitting shall be located on the curb side of the machine . A positive air gap , anti - siphon system shall in incorporated to protect the potable water supply . Y N 3 . A 2 - 1 / 2 ” hose storage rack shall be supplied ridged mounted to the machine . Y N C . WATER PUMP : 1 . Pump shall be positive displacement , heavy duty , and single acting triplex type having a capacity of at least 40 GPM at 2 , 000 PSI . Y N 2 . Pump shall have solid ceramic plungers and be capable of continuous operation at maximum designed pressure as well as running dry without damage . The run dry feature shall not require any type of clutch or low water warning system . Y N 3 . Pump shall consist of three ( 3 ) cylinders for smooth operation . In addition , the pump shall be protected from over pressurizing by a pressure relief valve . Y N 4 . Blowout disc safety relief systems are not acceptable as they are prone to nuisance failures . Y N 5 . Pump should have an air gap between the crankcase and plunger to prevent water from entering the crankcase in the event of valve failure . Y N 6 . Pump suction to be constructed of corrosion resistant piping with integral “ Y ” strainer for protecting the pump suction . Y N 7 . Pump shall be capable of pumping fresh , salt , and brackish water as well as specified chemicals without damage to the pump . In addition , the pump shall be rated for temperatures of at least 120 degrees . Y N 8 . Pump suction system must have a single air bleed valve for air removal . Y N 9 . Pump shall have an oil sight gauge . Y N 10 . The water pump shall be equipped with an Air Purge System for protection to high - pressure pump and hose during freezing conditions . Y N 11 . As standard equipment , the unit will have a recirculating valve that allows the operator to run water through the entire jetting system during cold weather operations . Y N 12 . The water pump shall be equipped with drain valves for protection during freezing conditions . Y N

Location

Country

United States of America (USA)

State

Georgia

Source

Source

Georgia Purchasing Group

URL

More Details

Record type

Tender

Sector

Water Supply and Storage, Chemical (Industrial), Oil and Gas, Waste Processing and Treatment, Metal, Steel, Manufacturing (Industrial)