logo

USCGC MUNRO LOAD BANK TESTING

Bids closed Apr 2026 · California · Last reported Apr 2026

Source: California Purchasing Group

Tender
Closed

This is a combined synopsis / solicitationThis is a combined synopsis / solicitation for commercial items / services prepared in accordance with the format in FAR Subpart 12 . 6 as supplemented with additional information included in this notice . Request for Quotations number is 70Z08526Q024134 and is issued as a r

Status
Closed
Sector
Oil and Gas, Metal, Power Generation (CCGT), Warehouse, Government, Commercial, Seaport, Road
Location
California, United States of America
Updated
3 Nov 2026
Source
California Purchasing Group

ConstructChat

Ask ConstructChat about USCGC MUNRO LOAD BANK TESTING

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “USCGC MUNRO LOAD BANK TESTING” is a tender record in Taiyo, linked to the Oil and Gas sector. It is issued for works, goods, or services related to California, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

This is a combined synopsis / solicitationThis is a combined synopsis / solicitation for commercial items / services prepared in accordance with the format in FAR Subpart 12 . 6 as supplemented with additional information included in this notice . Request for Quotations number is 70Z08526Q024134 and is issued as a request for quotations ( RFQ ). This announcement constitutes only solicitation ; quotations are being requested , and a written solicitation will not be issued . This Request for Quotations incorporates provisions and clauses in effect through Federal Acquisition Circular 2005 - 65 dated January 29 , 2013 . The NAICS Code is 336611 . The small business size standard is 1250 . This is a totally small business set aside . All responsible sources may submit proposals that will be considered by the agency . The contract will be awarded on a firm - fixed - price basis using simplified acquisition procedures in accordance with FAR Part 13 . 5 . All responses from interested vendors must be received on / before 0800 Pacific Time , April 27 , 2026 , and will be reviewed by the Government . The United States Coast Guard Surface Force Logistics Center has a requirement for the following : Contractor shall provide parts requested for USCGC Munro Load Bank Testing : SOW for # 2 & # 3 SSDGs Load Bank TestingUSCGC MUNRO ( WMSL - 755 ) This solicitation is to provide : Load bank testing of the # 1 & # 2 SSDGs for CGC MUNROVendor to Perform work at ships homeport : CGC MUNROUNITED STATES COAST GUARD BASE ALAMEDA1 EAGLE ROAD ALAMEDA , CA 94501Security requirements : No special security requirements needed . Vendor will only require base and ship access during POP . POP : 28APR2026 – 26MAY2026POC : MUNRO Engineer Officer : LCDR John Hamel ( 571 ) 608 - 4553MUNRO Port Engineer : LTJG Bethani Hartman ( 571 ) 608 - 9108MUNRO APM : LTJG David Robbins ( 808 ) 373 - 615531100_BEC_0924_418ITEM 1 : WORK ITEM 1 : Ship Service Diesel Generator , Load testing , perform1 . SCOPEz1 . 1Intent . This work item describes the requirements for the Contractor to perform load testing of designated Ship Service Diesel Generator ( i . e ., SSDG ) listed in Table 1 . TABLE 1 – LIST OF SHIP SERVICE GENERATORCATERPILLAR mODEL NO . DESCRIPTIONlocation3512BNo . 02 Ship Service Diesel Generator ( NSC 009 ), 1360 KW , 450 Volt AC , 3 Phase , 60 HzAuxiliary Machinery Room ( 5 - 36 - 01 - E ) 3512BNo . 03 Ship Service Diesel Generator ( NSC 009 ), 1360 KW , 450 Volt AC , 3 Phase , 60 HzShip Service Diesel Generator Room ( 7 - 76 - 5 - Q ) 1 . 2Government - furnished property . None . 2 . REFERENCESCoast Guard DrawingsCoast Guard Drawing 750 - WMSL - 501 - 002 , Rev E , Machinery Arrangements ( ASC501001 ) Coast Guard Drawing 418A - WMSL - 801 - 002 , Rev A , Booklet of General PlansCoast Guard PublicationsSurface Forces Logistics Center Standard Specification 0000 ( SFLC Std Spec 0000 ), 2022 , General RequirementsCoast Guard Technical Publication ( TP ) 7119 , Ship Service Diesel Generator - Model 3512BCoast Guard Technical Publication ( TP ) 7165B , Ship Service Switchboards 1S , 2S , 3S & 1SP Shore Power – Operation , Maintenance & Installation – Volume 1Coast Guard Technical Publication ( TP ) 7166B , Ship Service Switchboards 1S , 2S , 3S & 1SP Shore Power – Operation , Maintenance & Installation – Volume 2 & 4Coast Guard Technical Publication ( TP ) 7167 , Ship Service Switchboards 1S , 2S , 3S & 1SP Shore Power – Operation , Maintenance & Installation – Volume 3Other ReferencesCOMDTINST 9077 . 1 ( series ) Equipment Lockout - Tags - Plus InstructionMIL - STD - 1310 , Sep 2009 , Shipboard Bonding , Grounding , and Other Techniques for Electromagnetic Compatibility and Safety3 . REQUIREMENTS3 . 1General . 3 . 1 . 1CIR . None . 3 . 1 . 2Tech Rep . None . 3 . 1 . 3Protective measures . The Contractor must furnish and install all protective measures in accordance with SFLC Std Spec 0000 , paragraph 3 . 3 . 3 ( Vessel component , space , and equipment protection ). 3 . 1 . 4Interferences . The Contractor must handle all interferences in accordance with SFLC Std Spec 0000 , paragraph 3 . 3 . 5 ( Interferences ). Known interferences include , but are not limited to the following : PipingElectrical CablesSwitchboard EnclosureVent DuctingMotor Operated Valves3 . 1 . 5Background information . SSDG listed in Table 1 will be modified by the Coast Guard for the following task : Generator Bearing ReplacementShaft AlignmentPinning and Machine WorkDiesel Engine Top - end Overhaul3 . 1 . 5 . 1 After completion of above listed tasks , this Work Item is to be used for the Contractor to perform load testing of designated SSDG listed in Table 1 . 3 . 2Work location . The concerned work area is listed in Table 1 . See the applicable drawings in References in Paragraph 2 for guidance , locations , and details . 3 . 2 . 1 Proposed temporary cable routing must be developed using USCG Dwg 418A - WMSL - 801 - 001 . Submit a CFR . 3 . 2 . 1 . 1 Temporary load bank cables must be routed from the switchboard to the load bank via a single route , and must not be routed separately by any method which would lead to unbalanced phase cables to transit through hull or bulkhead openings . 3 . 3Grounding . The Contractor must ensure conductive surfaces of the load bank enclosure are appropriately bonded and grounded for protection of personnel . 3 . 4Contractor Furnished Materials ( CFM ). The Contractor must furnish materials listed in the Table 2 for load testing of the SSDG listed in Table 1 . TABLE 2 – CONTRACTOR furnish MATERIALSMATERIALSdescriptionSOURCE OF SUPPLYLoad Bank1500 KW , 450 Volt AC , 3 Phase , 60 Hz , ResistiveElectrical Equipment ’ s Rental CompanyLoad Bank CablesApproximate length of 300 Feet Cables with ring tongue compression lugs , 6 Paralleled # 4 / 0 copper ( single conductor ) per phase ( 18 Total x 300 Feet ) and one additional length for the equipment grounding conductor or Six LSTSGU - 400Tony SantiagoMurray Benjamin Electric397 West Ave . Stamford CT 06902 ( 203 - 705 - 2100 ) OR Any Electrical Cable Supplier3 . 4 . 1 The contractor must provide miscellaneous hardware required for electrical installation ( i . e . Nylon Stuffing Tubes , Chafing Gear , Box Connectors , Lugs , Fasteners , Wire Nuts , Tapes , Cable ties & Cable Mounting Brackets , etc ) of the electrical equipment . 3 . 5Load testing . The Contractor must provide labor and crane services as necessary for placing load bank at suitable location ( i . e ., On the pier or the ship ). After completion of load bank testing of SSDG , the Contractor must remove all installed equipment and cables used during testing . 3 . 5 . 1Testing plan . The Contractor must submit a plan for load testing of the SSDG in accordance with TP 7119 . 3 . 5 . 1 . 1 The plan must cover the following topics at a minimum : Steady increase of load in multiple steps up to 100 % real power loadNo less than 2 hours of continuous testing at 100 % loadSimulated start of 450 HP load ( assume no more than 200 % FLA ) Emergency shutdown proceduresLoad bank specification and locationCable locations for load bankNo - load testsData to be collected during testsAll proposed connections , cable and load bank configurations3 . 5 . 1 . 2 The Contractor must start testing of the SSDG after COR Approval of submitted Test Plan and official acceptance by the Contract Officer ( KO ). 3 . 5 . 2 After placing load bank at suitable location ( i . e ., On the pier or the ship ) the Contractor must install the cables from the load bank to associated SS Switchboard bus bars ( i . e . Back side of SS Switchboard No . 2S ), according to the agreed upon cable routing . CAUTIONTHE BACK SIDE OF THE SWITCHBOARD SHOULD BE ROPED OFF AS A PERSONNEL EXCLUSION AREA ( APPROXIMATELY 10 FOOT RADIUS FROM ANY VISIBLE LIVE BUS3 . 5 . 2 . 1 The Contractor must route the cables from designated SSDG to load bank through hatches and passageway . The Contractor must run cables in overheads as much as possible to avoid trip hazards . NOTECoast Guard personnel will operate all shipboard machinery and equipment . SAFETYAt any point in the load test or operational testing period if the need presents itself the engine – Prime mover may be shut down by the Tech rep with communication to the USCG operational Engineer utilizing the local EOS , E stop or shut down from the switch gear . Any of the three options will automatically open the SSDG buss breaker3 . 5 . 3 After warmup of SSDG until coolant temperature reaching 140 Degree F , the Contractor must perform the load testing of designated SSDG listed in Table 1 at following load condition . TABLE 3 – LOAD TESTINGLOADHOURS * No Load0 . 5 Hrs25 % Load0 . 5 Hrs50 % Load0 . 5 Hrs75 % Load0 . 5 Hrs100 % Load2 . 0 HrsNo Load0 . 5 HrsRunning no load testing . No load testing will consist of running the engine at idle rpm until the engine coolant temperature reaches 140 deg . F during that warmup time safety testing will be performed for oil pressure , temp warning , emergency shut down conditions , and coolant temp . warning and shutdown . Shipboard alarm verification will be observed at that time as well . 3 . 5 . 3 . 1 Engine parameter readings during the load bank test must be taken every 15 minutes including , but not limited to the bullet points in this paragraph . Submit a CFR . Engine temp , Coolant temp , oil pressure , boost pressure , intake air temp after the aftercooler , exhaust stack temp , left and right bank exhaust temperatures . In addition to the generator load test form , a Caterpillar steady state engine performance file shall be recorded on the engine ECM all related available information . Generator information , voltage reading per phase , amperage readings per phase , HZ , bearing and winding temps . Pre and post - test PSSRP shall be saved on the ECM to provide verification of all available diagnostic codes and events . All electronic files and reports must be submitted via CFR . 3 . 6Load test documentation . After completion of testing , the Contractor must provide all collected data sheets to the Contracting Officer . 4 . NOTESThis section is not applicable to this work item .

Location

Country

United States of America (USA)

State

California

Source

Source

California Purchasing Group

URL

More Details

Record type

Tender

Sector

Oil and Gas, Metal, Power Generation (CCGT), Warehouse, Government, Commercial, Seaport, Road

Article published date

2026-05-10

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender