logo

USCGC Sturgeon Bay MPCMS Grooming

One of 10,000+ tenders Taiyo tracks in New Jersey.

Source: New Jersey Purchasing Group

Tender
Closed

This is for informational purposes only . This has been awarded VIA JOTFOCUNITED STATES COAST GUARDCUTTER STURGEON BAY ( WTGB - 109 ) ENGINEERING DEPARTMENTScope of WorkMPCMS Grooming – 140 - ft Icebreaking TugPOP : 05 - 09 JAN 20261 . PurposeProvide contractor services to inspect , groom , and verify proper operation of the

Status
Closed
Location
New Jersey, United States of America
Updated
3 Nov 2026
Source
New Jersey Purchasing Group

ConstructChat

Ask ConstructChat about USCGC Sturgeon Bay MPCMS Grooming

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “USCGC Sturgeon Bay MPCMS Grooming” is a tender record in Taiyo. It is issued for works, goods, or services related to New Jersey, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

This is for informational purposes only . This has been awarded VIA JOTFOCUNITED STATES COAST GUARDCUTTER STURGEON BAY ( WTGB - 109 ) ENGINEERING DEPARTMENTScope of WorkMPCMS Grooming – 140 - ft Icebreaking TugPOP : 05 - 09 JAN 20261 . PurposeProvide contractor services to inspect , groom , and verify proper operation of the Machinery Plant Control – Monitoring System ( MPC - MS ) aboard Coast Guard Cutter STURGEON BAY ( WTGB - 109 ). All work shall support operational readiness and be conducted IAW Coast Guard engineering policy and cutter requirements . 2 . Required Contractor Actions • Conduct a full - system inspection of MPC - MS hardware , PLCs , HMIs , sensors , and all communication paths .• Perform grooming tasks including reseating connectors , tightening terminations , correcting wiring discrepancies , eliminating false alarms , and ensuring proper labeling .• Verify correct operation of monitored propulsion systems , auxiliary equipment , tank levels , steering / hydraulic readouts , and alarm annunciation .• Calibrate temperature , pressure , and level sensors using certified and traceable calibration equipment .• Install approved software / firmware updates with PL / EPO authorization . 3 . Testing Requirements • Conduct operational testing across propulsion , electrical generation , auxiliary systems , and safety monitoring .• Validate alarm setpoints , annunciation , communications integrity , and correct event logging .• Confirm accurate data reporting to all MPCMS HMIs and operator stations . 4 . Deliverables • Written MPCMS Grooming Report detailing inspections performed , discrepancies identified , corrective actions , and future recommendations .• Calibration certificates and updated system documentation , as applicable .• List of replaced components including part numbers and serial numbers . 5 . CoordinationContractor shall coordinate all work directly with the Engineer Petty Officer ( EPO ), ensuring system outages are scheduled and cutter readiness is maintained . 6 . Completion CriteriaWork will be considered complete when :• No unresolved MPCMS faults remain • All alarms function properly • All calibrated sensors meet required tolerances • Updated documentation is submitted • EPO signs off on system performance7 . UNIT POC : MKCM Thaddeus BrandtEngineer Petty OfficerCGC Sturgeon BAY85 PORT TERMINAL BLVD , SLIP 3BAYONNE , NJ 07002US201 - 912 - 7910

Location

Country

United States of America (USA)

State

New Jersey

Source

Source

New Jersey Purchasing Group

URL

More Details

Record type

Tender

Article published date

2026-04-29

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender