1 . STATEMENT OF WORKThe contractor shall furnish all requisite services , labor , travel , transportation , materials , shipping , parts , connections , and equipment for the provision and on - site installation of a minimum of threevaporized hydrogen peroxide Low Temperature Sterilizers . These units are to be located at 48

Status
Closed
Sector
Hospital, Power Transmission, Hydrogen, Power Generation (CCGT), Commercial, Residential
Location
Missouri, United States of America
Updated
3 Nov 2026
Source
Missouri Purchasing Group

ConstructChat

Ask ConstructChat about VPRO Max2 Low Temp Sterilizers

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “VPRO Max2 Low Temp Sterilizers” is a tender record in Taiyo, linked to the Hospital sector. It is issued for works, goods, or services related to Missouri, United States of America.

Participants

Not available for this record.

Status

Original status

closed

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

1 . STATEMENT OF WORKThe contractor shall furnish all requisite services , labor , travel , transportation , materials , shipping , parts , connections , and equipment for the provision and on - site installation of a minimum of threevaporized hydrogen peroxide Low Temperature Sterilizers . These units are to be located at 4801Linwood Blvd , Kansas City MO 64128 . These low temperature sterilizers are essential for the SterileProcessing Service ( SPS ) in reprocessing reusable medical devices ( RMDs ) employed in invasiveprocedures . needed to support Sterile Processing Service ( SPS ) for reprocessing reuseable medicaldevices ( RMD ) used in invasive procedures . Furthermore , these units are critical for supportingmedical procedures and surgeries and surgeries conducted within the Operating Room , as well asin various ancillary clinics throughout the KCVA . The contractor shall additionally furnish training to clinical personnel prior to the utilization of theequipment . This training is to encompass all tours of duty for the sterile processing department andnecessitate annual retraining on all associated on all associated equipment . Moreover , thecontractor bears the responsibility for the removal and disposal of all debris and packagingmaterial resulting from the installation of the VPRO MaX2 Low Temp Sterilizers . 2 . SPECIFICATIONS • Three low temperature sterilizers shall have a minimum individual dimensions of Cabinet ( DD ): 33 x 40 - 15 / 16 x 72 ” ( 838 x 1040 x 1829 mm ) with Recessed / Cabinet ( SD ): 33 x38 - 5 / 16 x 72 ” ( 838 x 973 x 1829 mm ). o Mounting single door , cabineto System installation requires no plumbing , ventilation or airo supply – only a dedicated electrical connection is needed . A power cord is suppliedfor this connectiono The facility space in which the vehicle can occupy is approx . 35 ’ x 110 ’.• Vaporized hydrogen peroxide sterilization processes are particularly suited for sterilizingheat - sensitive materials because temperatures within the load currently do not exceed55ºC ( 131ºF ) and sterilization occurs in a low - moisture environment . Heat tolerant devicesand materials can also be indicated for vaporized hydrogen peroxide sterilization processes . FDA - cleared vaporized hydrogen peroxide sterilizers , either with or without plasma , arecurrently available in the United States . Per ANSI / AAMI ST58 : 2013 or subsequent , the sterilizer shall be installed and operated inan area with a ventilation system capable of at least 10 air exchanges per hour . VPRO MaX2 must support utility requirements : o Current 16 AMPo Minimum Circuit Breaker 20 AMPSo Use NEMA L15 - 20R Plugo Provide grouped or ganged circuit protection and disconnect for phase 3 power asrequired by NEC and local codes . o Individual power shutoffs near each machine for servicing . Shall integrate with the CensiTrac Instrument Tracking System .

Location

Country

United States of America (USA)

State

Missouri

Source

Source

Missouri Purchasing Group

URL

More Details

Record type

Tender

Sector

Hospital, Power Transmission, Hydrogen, Power Generation (CCGT), Commercial, Residential

Article published date

2026-04-29

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender