TABLE 1: Water Quality Routine Testing Frequency for Critical Water, Utility Water, AER Final Rinse, and Steam Condensate for each (Brooklyn and Manhattan) of the Medical Centers will be: Water Quality Measurement Source Sampling Site(s) # of Samples per event Sampling Frequency # of Samples per year MANHATTAN & BROOKLYN pH Critical Water After the last treatment step at the water generation syste

Status
Prospective
Sector
Metal, Steel, Fertilizers, Commercial, Residential, Water Supply and Storage, Power Transmission, Hospital, Power Generation (CCGT)
Location
United States of America
Updated
3 Nov 2026
Source
SAM.gov

ConstructChat

Ask ConstructChat about W065--Lease Sps Reverse Osmosis - Brooklyn & Manhattan Vamc

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “W065--Lease Sps Reverse Osmosis - Brooklyn & Manhattan Vamc” is a tender record in Taiyo, linked to the Metal sector. It is issued for works, goods, or services related to United States of America.

Participants

Not available for this record.

Status

Original status

solicitation

Taiyo status

Prospective

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

TABLE 1: Water Quality Routine Testing Frequency for Critical Water, Utility Water, AER Final Rinse, and Steam Condensate for each (Brooklyn and Manhattan) of the Medical Centers will be: Water Quality Measurement Source Sampling Site(s) # of Samples per event Sampling Frequency # of Samples per year MANHATTAN & BROOKLYN pH Critical Water After the last treatment step at the water generation system At the point the distribution loop enters the processing area or first POU on the distribution loop 2 Monthly 24 Conductivity Critical Water At the point the distribution loop enters the processing area or first POU on the distribution loop 1 Monthly 12 Total Alkalinity Critical Water After the last treatment step, storage tanks At the point the distribution loop enters the processing area or first POU on the distribution loop 2 Monthly 24 Total Hardness Critical Water After the last treatment step At the point the distribution loop enters the processing area or first POU on the distribution loop 2 Monthly 24 BROOKLYN Bacteria Critical Water Loop out point Loop return point Each location of point-of-use in department (subject to change): Decon Sink Scope Sink Unity Ultrasonic Washer-Disinfector #1 Washer-Disinfector #2 7 Monthly 84 Endotoxin Critical Water Water storage tank Loop out point Loop return point Each location of point-of-use in department (subject to change): Decon Sink Scope Sink Unity Ultrasonic Washer-Disinfector #1 Washer-Disinfector #2 8 Monthly 96 MANHATTAN Bacteria Critical Water Loop out point Loop return point Each location of point-of-use in department (subject to change): Decon Sink #1 Decon Sink #2 Decon Sink #3 Decon Sink #4 Scope Sink #1 Scope Sink #2 Caviwave PRO Ultrasonic #1 Caviwave PRO Ultrasonic #2 Caviwave PRO Ultrasonic #3 Caviwave PRO Ultrasonic #4NY - will eventually have 4 ultrasonic Ok Washer-Disinfector #1 Washer-Disinfector #2 Washer-Disinfector #3 15 Monthly 156 Endotoxin Critical Water Water storage tank Loop out point Loop return point Each location of point-of-use in department (subject to change): Decon Sink #1 Decon Sink #2 Decon Sink #3 Decon Sink #4 Scope Sink #1 Scope Sink #2 Caviwave PRO Ultrasonic #1 Caviwave PRO Ultrasonic #2 Caviwave PRO Ultrasonic #3 Caviwave PRO Ultrasonic #4 Washer-Disinfector #1 Washer-Disinfector #2 Washer-Disinfector #3 16 Monthly 168 MANHATTAN & BROOKLYN Total Organic Carbon (TOC) Critical Water After the last treatment step At the point the distribution loop enters the processing area or first POU on the distribution loop 2 Quarterly 8 Ionic Contaminants Aluminum Chloride Copper Iron Manganese Nitrate Phosphate Sulfate Silicate Zinc Critical Water After the last treatment step At the point the distribution loop enters the processing area or first POU on the distribution loop 2 Quarterly 8 pH Utility Water At the point the distribution loop enters the processing area or first POU on the distribution loop 1 Quarterly 4 Conductivity Utility Water At the point the distribution loop enters the processing area or first POU on the distribution loop 1 Quarterly 4 Total Alkalinity Utility Water At the point the distribution loop enters the processing area or first POU on the distribution loop 1 Quarterly 4 Total Hardness Utility Water At the point the distribution loop enters the processing area or first POU on the distribution loop 1 Quarterly 4 BROOKLYN Bacteria Utility Water Each location of point-of-use in department (subject to change): Decon Sink Scope Sink Unity Ultrasonic Washer-Disinfector #1 Washer-Disinfector #2 5 Quarterly 20 MANHATTAN Bacteria Utility Water Each location of point-of-use in department (subject to change): Decon Sink #1 Decon Sink #2 Decon Sink #3 Decon Sink #4 Scope Sink #1 Scope Sink #2 Caviwave PRO Ultrasonic #1 Caviwave PRO Ultrasonic #2 Caviwave PRO Ultrasonic #3 Caviwave PRO Ultrasonic #4 Washer-Disinfector #1 Washer-Disinfector #2 Washer-Disinvector #3 13 Quarterly 44 Total Organic Carbon (TOC) Utility Water At the point the distribution loop enters the processing area or first POU on the distribution loop 1 Quarterly 4 Ionic Contaminants Aluminum Chloride Copper Iron Manganese Nitrate Phosphate Sulfate Silicate Zinc Utility Water At the point the distribution loop enters the processing area or first POU on the distribution loop 1 Quarterly 4 BROOKLYN pH Steam Steam Sterilizer Cooler Sample Port 1 Quarterly 4 Conductivity Steam Steam Sterilizer Cooler Sample Port 1 Quarterly 4 Total Alkalinity Steam Steam Sterilizer Cooler Sample Port 1 Quarterly 4 Total Hardness Steam Steam Sterilizer Cooler Sample Port 1 Quarterly 4 Ionic Contaminants Steam Steam Sterilizer Cooler Sample Port 1 Quarterly 4 Bacteria Automated Endoscope Reprocessor Medivator #27 Right Basin Medivator #27 Left Basin Medivator #28 Right Basin Medivator #28 Left Basin 4 Monthly 48 Endotoxin Automated Endoscope Reprocessor Medivator #27 Right Basin Medivator #27 Left Basin Medivator #28 Right Basin Medivator #28 Left Basin 4 Monthly 48 MANHATTAN pH Steam Steam Sterilizer Cooler Sample Port 2 Quarterly 8 Conductivity Steam Steam Sterilizer Cooler Sample Port 2 Quarterly 8 Total Alkalinity Steam Steam Sterilizer Cooler Sample Port 2 Quarterly 8 Total Hardness Steam Steam Sterilizer Cooler Sample Port 2 Quarterly 8 Ionic Contaminants Steam Steam Sterilizer Cooler Sample Port 2 Quarterly 8 Bacteria Automated Endoscope Reprocessor Medivators #1 Right Basin Medivators #1 Left Basin Medivators #2 Right Basin Medivators #2 Left Basin Medivators #3 Right Basin Medivators #3 Left Basin 6 Monthly 72 Endotoxin Automated Endoscope Reprocessor Medivators #1 Right Basin Medivators #1 Left Basin Medivators #2 Right Basin Medivators #2 Left Basin Medivators #3 Right Basin Medivators #3 Left Basin 6 Monthly 72

Original sector

Utilities

Location

Country

United States of America (USA)

Source

Source

SAM.gov

URL

More Details

Record type

Tender

Sector

Metal, Steel, Fertilizers, Commercial, Residential, Water Supply and Storage, Power Transmission, Hospital, Power Generation (CCGT)

Article published date

2026-06-05

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender