Walk - in Freezer Replacement
Sector: Water Supply and Storage • Location: Alabama, United States of America
Source: Alabama Purchasing Group
Freezer shall maintain - 10 ° F to 0 ° F internal temperature under full load conditions . System shall be designed to maintain temperature during peak summer ambient conditions typical to Central Alabama . PRODUCTS : A . Furnish one ( 1 ) indoor walk - in freezer to be actual 15 ’- 5 “ x 15 ’- 5 ” x 9 ’ 6 “. B . Walk -
- Status
- Closed
- Sector
- Water Supply and Storage, Metal, Steel, Geothermal, Chemical (Industrial), Manufacturing (Industrial), Oil and Gas
- Location
- Alabama, United States of America
- Updated
- 3 Nov 2026
- Source
- Alabama Purchasing Group
ConstructChat
Ask ConstructChat about Walk - in Freezer Replacement
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | Freezer shall maintain - 10 ° F to 0 ° F internal temperature under full load conditions . System shall be designed to maintain temperature during peak summer ambient conditions typical to Central Alabama . PRODUCTS : A . Furnish one ( 1 ) indoor walk - in freezer to be actual 15 ’- 5 “ x 15 ’- 5 ” x 9 ’ 6 “. B . Walk - in freezer is to comply with the US Energy Independence & Security Act . C . Interior wall finish to be 190 Series embossed white galvanized . Exterior finish to be 190 Series embossed white galvanized . Interior ceiling finish to be 190 Series embossed white galvanized . Exterior ceiling finish to be 190 Series embossed white galvanized . Ceiling to be single span with no additional support required . Floor to be supplied with a reinforced 16ga galvanized floor . ¾ ” Plywood underlayment required on floor panels . Freezer floor to be covered in Protect - All Non - Slip rubber flooring . Non - slip rubber flooring shall have 8 ” cove base that will be capped off with stainless steel . Rubber flooring to be scheduled and installed through THG - D . D . Provide 48 ” high minimum 1 / 8 ”, 0 . 125 ”, textured aluminum tread plate on exposed exterior . E . Panels shall be equipped with Bally Speed - Loc diaphragmatic joining devices . The distance between locks shall not exceed 46 ”. Each device shall consist of a cam action , hooked locking arm placed in one panel , and a steel rod positioned in the adjoining panel , so that when the arm is rotated , the hood engages the rod and draws the panels tightly together with cam action . Arms and rods shall be housed in individual steel pockets . Pockets on one side of the panel shall be connected to pockets on the other side in width , by use of 2 ” wide metal straps set into and completely surrounded by insulation . When panels are joined these straps shall form lock - to - lock connections for superior strength . Locking device shall be accessible from the inside to facilitate installations in confined areas and shall be provided with flush press - fit caps . Surface mounted plastic plugs will not be accepted . F . Panels shall consist of interior and exterior metal skins precisely foamed with steel dies and roll - form equipment and thoroughly checked with gauges for accuracy . Metal skins shall be treated on the inside surface with a bonding agent to ensure a stable adhesion with the chemical bonding agents of the urethane . Urethane shall be Enovate 3000 or Solstice foamed in place ( poured , not frothed ) and , when completely cured , shall bind tenaciously to metal skins to form an insulated panel . Panels shall contain 100 % urethane insulation and have no internal wood or structural members between skins unless required as structural support for external accessories . To ensure tight joints , panel edges must have foamed - in place tongue and groove with flexible vinyl gasket foamed - in place on the interior and exterior of all tongue edges . Gaskets shall be resistant to damage from oil , fats , water and detergents and must be NSF - approved . Gaskets shall not be stapled or glued to metal skins . All panels ( except corner panels ) shall be made in 23 ” and 46 ” widths , fully interchangeable for fast , easy assembly . 11 - 1 / 2 ", 17 - 1 / 4 ", 34 - 1 / 2 " wide are to be furnished only if required to fit allocated space . To ensure perfect alignment and maximum strength , corner panels shall employ a right - angle configuration with exterior horizontal dimensions of 12 ” on each side . G . Unit shall be fitted with freezer door with 36 " x 78 " swing out type hinged entrance door . Door finishes to be 22GA embossed stainless exterior doors and frame . a . Doors shall be flush mounted , in - fitting type will have a 14 - gauge unitized structural “ U ” channel steel door frame with 1 / 8 ” steel plates where all hardware is mounted . The steel frame with an internal thermal breaker will prevent twisting , sagging , and eliminates the need for structural members . b . Door shall be equipped with a magnetic steel core gasket across the top and both sides of the door . c . Bottom of the door shall be fitted with adjustable , double vinyl wiper gasket . NSF approved removable gasket . d . Each door frame shall be provided with an LED vapor proof light fixture . e . Doors and door handles shall be Kason 27C satin aluminum finish and listed by U . L and an inside safety release . f . A positive action Kason 1094 hydraulic door closer shall be included to ensure gentle closing action of door and ensure a positive seal . g . Provide each door with ( 3 ) heavy - duty adjustable / spring assisted Kason 1346 satin aluminum hinges . Hinges shall be cam - lift , self - closing type , ” hold - open ” feature allowing door to remain open unaided , when opened to 180 degrees position . h . Door frames shall be provided with a 2 " diameter flush - face dial thermometer . i . Doors provided with thermostatically controlled warmer cable around entire perimeter of opening |
Location
Country | United States of America (USA) |
State | Alabama |
Source
Source | Alabama Purchasing Group |
URL |
More Details
Record type | Tender |
Sector | Water Supply and Storage, Metal, Steel, Geothermal, Chemical (Industrial), Manufacturing (Industrial), Oil and Gas |
Article published date | 2026-03-27 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender
More Water Supply and Storage tenders in United States of America
- RFP - Thurston County Lake Management Districts Submerged Aquatic Vegetation Control
- Coatings for Wet Well and Manholes
- Sole Source for Wedeco UV BulbsBallets
- Security Hardware Services
- Chambers Creek Regional Wastewater Treatment Plant BNR Aeration Basin Airflow Meters
- Se Dixie Highway County Road A1A Utility Relocation Project
- UNPAINTED SNOW FENCE AND DUNE GRASS NO II
- PreQualification of Bidders for Chaboya Improvements