Z -- Ulysses S . Grant NHS - Geothermal System Leak Detection
Sector: Government • Location: Missouri, United States of America
Source: Missouri Purchasing Group
Ulysses S . Grant NHS - St . Louis , MO - Geothermal System Leak DetectionSOURCES SOUGHT ( MARKET SURVEY ): The National Park Service ( NPS ) is conducting a market survey to determine the interest and capability of contractors for an upcoming project . All costs associated with providing information in response to th
- Status
- Closed
- Sector
- Government, Geothermal
- Location
- Missouri, United States of America
- Updated
- 3 Nov 2026
- Source
- Missouri Purchasing Group
ConstructChat
Ask ConstructChat about Z -- Ulysses S . Grant NHS - Geothermal System Leak Detection
Pick a question to edit it, or write your own.
First answer free · no account
Tender Information FAQ
Tender Information
Participants
| Not available for this record. |
Status
Original status | closed |
Taiyo status | Closed |
Taiyo last update | 2026-11-03 |
Contact
| Not available for this record. |
Description
Description | Ulysses S . Grant NHS - St . Louis , MO - Geothermal System Leak DetectionSOURCES SOUGHT ( MARKET SURVEY ): The National Park Service ( NPS ) is conducting a market survey to determine the interest and capability of contractors for an upcoming project . All costs associated with providing information in response to this market survey shall be the responsibility of the firm . Any information submitted is voluntary . The Contracting Officer will make an acquisition strategy determination based on the results of this market survey . Work will consist of detecting a leak within the geothermal heating and cooling system at Ulysses S . Grant NHS in St . Louis , MO . Leak volume is approximately 40 gallons per day . Leak is currently isolated to one of the five system laterals and that lateral is disabled . Leak may be within the lateral or may be within one of the five vertical bores . Lateral length is approximately 80 yards . All laterals , vertical bore heads , and interfaces between each are located no less than 5 ft below ground surface ; individual bores cannot be isolated . Leak detection shall be non - invasive . Recommended method is helium leak detection . The NAICS code for this project is 221330 - Steam and Air Conditioning Supply . A registration within the System for Award Management is required . This market research is being conducted to locate potential contractors that may be interested in performing this work . This is not an invitation for bid ( IFB ), request for proposal ( RFP ), nor Request for Quote ( RFQ ) and does not constitute any commitment by the Government to issue any solicitation . All interested firms must respond to future solicitation announcements separately from responses to this market survey . Any solicitation that may be issued will be posted on SAM . gov . Interested parties shall contact the contracting officer at matthew_frank @ nps . gov . Please reference the posting number , 140P6226Q0001 , in your email subject line . Include company name , SAM UEI , and leak detection capabilities in the email body . Phone and text messages are NOT recommended . |
Location
Country | United States of America (USA) |
State | Missouri |
Source
Source | Missouri Purchasing Group |
URL |
More Details
Record type | Tender |
Sector | Government, Geothermal |
Article published date | 2026-04-29 |
Research
Free account
View all details
You are reading the public part. A free account opens the rest:
- Every detail on this tender
- News and media coverage
- Technical research
Free account · no card · lands you back on this tender