logo

Z1Da--Replace Condensate Lines And Pumps 585-21-113 Construction (Va-26-00027136)

The scope, dates and status of this tender. A free account opens every field.

Source: SAM.gov

Tender
Solicitation

SOLICITATION 36C25226B0005 AMENDMENT A0001 February 24, 2026 Project: Replace Condensate Lines Construction Project Number: 585-21-113 Location: Oscar G Johnson VAMC Hospital Amendment 0001 hereby incorporates the following clarifications/change(s) into the solicitation package. RFI Question and Responses RFI # CONTRACTOR QUESTIONS REFERENCE VA RESPONSE 1 To mitigate any potential complications wi

Status
Closed
Sector
Steel, Road, Hospital, Commercial, Hydro, Metal, Residential
Location
Iron Mountain, Michigan, United States of America
Updated
3 Nov 2026
Source
SAM.gov

ConstructChat

Ask ConstructChat about Z1Da--Replace Condensate Lines And Pumps 585-21-113 Construction (Va-26-00027136)

Pick a question to edit it, or write your own.

First answer free · no account

I am a

Tender Information FAQ

Tender Information

3 Q
The tender “Z1Da--Replace Condensate Lines And Pumps 585-21-113 Construction (Va-26-00027136)” is a tender record in Taiyo, linked to the Steel sector. It is issued for works, goods, or services related to Iron Mountain, Michigan, United States of America.

Participants

Not available for this record.

Status

Original status

solicitation

Taiyo status

Closed

Taiyo last update

2026-11-03

Contact

Not available for this record.

Description

Description

SOLICITATION 36C25226B0005 AMENDMENT A0001 February 24, 2026 Project: Replace Condensate Lines Construction Project Number: 585-21-113 Location: Oscar G Johnson VAMC Hospital Amendment 0001 hereby incorporates the following clarifications/change(s) into the solicitation package. RFI Question and Responses RFI # CONTRACTOR QUESTIONS REFERENCE VA RESPONSE 1 To mitigate any potential complications with submitting a physical bid, either via mail or in person, would you consider changing the submission method to allow for electronic bids via email? Additionally, if this is to remain a mail or hand delivered bid submission, would you consider extending the bid opening to accommodate mailed submissions? With the bid being due on a Monday morning, mail in submissions would need to be sent out on the previous Friday. This leaves open the possibility for last minute changes to develop over the weekend that cannot be taken into consideration by contractors submitting via mail. No electronic submittal. Bid date has been extended to 3/26/2026. 2 Drawings page size appears as 8.5x11 Drawings should be 42x30 - See attached drawings. 3 Is there a survey available for the asbestos mentioned in the specifications. Will it be released with the drawings? 221 times with instructions A survey will be available upon start of the contract. An estimate of quantity is listed on the prints page MD101 4 If there are any site access requirements, preferred site visit windows, or points of contact for field coordination, please advise. See pages 1&6 of Solicitation 5 1. On page 346 of the Specification section 2.3-B #3-b A193 Bolt, A194 Nut, F436 Washer are listed in red. Are these A193 B7 bolts with A 194 Grade 2H Nut please? 2. On page 350 of the Specification section 2.7-D #2 States (Trap bodies steel) Would a Armstrong Em series inverted bucket trap meet your requirements? Or Is a Cast Iron Trap body acceptable like a Armstrong 800 series which we have used exclusively on past projects. 3. On Page 354 of the Specification section 3.2-H #1 States (Perform Radiographic Examination).  Do you have a Radiographic Performance specification that is required to be meet? Or can we hydro test all work to 1.5 times operating pressure to meet the proof testing requirements as we have typically done on previous Oscar G Johnson projects? Pages 346. 350, and 354 Specification A survey will be available upon start of the contract. An estimate of quantity is listed on the prints page MD101 6 If there is a survey available for the asbestos mentioned in the specifications for IRON MOUNTAIN - 585-21-113 REPLACE CONDENSATE LINES. The topic is referenced 221 times, with instructions regarding both removal and installation prohibitions. Will the survey be released along with the drawings soon? Specification A survey will be available upon start of the contract. An estimate of quantity is listed on the prints page MD101 Requests for information (RFI s) Due Date No Change RFI s due Friday, 3/6/2026 no later than 3:00 PM Bid Opening Date extended from 3/23/2026 to: PROPOSAL DUE DATE / TIME: MARCH 26, AT 1:00 P.M. CST. Great Lakes Acquisition Center (GLAC) 115 S. 84th Street, Suite 101 Milwaukee, WI 53214-1476 Drawings S06 Att1 BD Set Rev2 ALL QUESTIONS REGARDING THIS SOLICITATION SHALL BE SENT TO THE FOLLOWING INDIVIDUALS: Donita Grace -- Donita.Grace@va.gov All bidders are responsible for monitoring and downloading any amendments from Contract Opportunities at the following website: https://sam.gov/content/opportunities Contractors shall ensure all amendments are acknowledged on Page 2 of the SF-1442.

Original sector

Construction

Location

Country

United States of America (USA)

State

Michigan

City

Iron Mountain

Source

Source

SAM.gov

URL

More Details

Record type

Tender

Sector

Steel, Road, Hospital, Commercial, Hydro, Metal, Residential

Article published date

2026-02-26

More on this tender

Research

Free account

View all details

You are reading the public part. A free account opens the rest:

  • Every detail on this tender
  • News and media coverage
  • Technical research
View all details

Free account · no card · lands you back on this tender